Evidence map›Paper›PMID 37193599›Full record

ArticleRespiratory care2023

Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter.

Morten Pallisgaard Støve, Aske Hostrup Graversen, Johanne Sørensen

Abstract read
In one paragraph

Article in Respiratory care, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Pulse Oximetry: 2023 Year in Review.Respiratory care · 2024
    Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Morten Pallisgaard StøveDepartment of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark. mps@ucn.dk.
Aske Hostrup GraversenDepartment of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark.
Johanne SørensenDepartment of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatients with COPD can have hypoxemia; hence, monitoring peripheral S

methodsThirty-six participants with COPD (20 women), ages 52-89 years, participated in this cross-sectional study. Oxygen saturation was concurrently measured by using the Contec Pulse Oximeter CMS50D as a comparator, and the Apple Watch Series 7 and the Garmin Vivosmart 4 at rest and immediately after the 30-s sit-to-stand test and the 6-min walk test (6MWT).

resultsFor the Apple Watch, the root mean squared error showed a deviation of 3.5% at rest, 4.1% after the 30-s sit-to-stand test, and 3.9% after the 6MWT. The level of agreement was 2.8 ± 2.4 (7.6, -1.9) at rest, 3.1 ± 2.8 (8.6, -2.3) after the 30-s sit-to-stand test, and 2.8 ± 2.9 (8.6, -2.9) after the 6MWT. For the Garmin Vivosmart, the root mean squared error showed a deviation of 3.3% at rest, 6.1% after the 30-s sit-to-stand test, and 5.4% after the 6MWT. Level of agreement was 1.9 ± 2.7 (7.2, -3.3) at rest, 2.9 ± 5.4 (13.5, -7.7) after the 30-s sit-to-stand test, and 2.3 ± 5.0 (12.1, -7.4) after the 6MWT. The limits of agreement showed considerable measurement variance and a tendency for the devices to be less accurate at lower saturation levels.

conclusionsThe Apple Watch Series 7 and Garmin Vivosmart 4 overestimated S

Indexed as

Pulmonary Disease, Chronic ObstructiveCross-Sectional StudiesExercise TestFemaleHumansOximetryOxygenOxygen SaturationOxygenCOPDoxygen saturationpulmonary rehabilitationrespiratory carevalidityWearable devices

Identifiers

PMID37193599
PMCPMC10353168

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.