ArticleAnnals of biomedical engineering2023
Development of Novel Balloon-Integrated Optical Catheter for Endoscopic and Circumferential Laser Application.
Article in Annals of biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Investigation of therapeutic potential of simultaneous triple-wavelength laser technology for skin rejuvenation.Lasers in medical science · 2025Article
- Comparative Evaluations on Real-Time Monitoring of Temperature Sensors during Endoscopic Laser Application.Sensors (Basel, Switzerland) · 2023Article
- Feasibility Study on Endoscopic Balloon-Assisted Laser Treatment (EBLT) of Gastroesophageal Reflux Disease (GERD) in In Vivo Porcine Model.Biomedicines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
The current study aims to demonstrate the feasibility of a novel balloon-integrated optical catheter (BIOC) to achieve endoscopic laser application for circumferential coagulation of a tubular tissue structure. Both optical and thermal numerical simulations were developed to predict the propagation of laser light and a spatio-temporal distribution of temperature in tissue. Ex vivo esophagus tissue was tested with 980 nm laser light at 30 W for 90 s for quantitative evaluations. In vivo porcine models were used to validate the performance of BIOC for circumferential and endoscopic laser coagulation of esophagus in terms of acute tissue responses post-irradiation. Optical simulations confirmed that a diffusing applicator was able to generate a circumferential light distribution in a tubular tissue structure. Both numerical and experimental results presented that the maximum temperature elevation occurred at 3-5 mm (muscle layer) below the mucosa surface after 90 s irradiation. In vivo tests confirmed the circumferential delivery of laser light to a deep muscle layer as well as no evidence of thermal damage to the esophageal mucosa. The proposed BIOC can be a feasible optical device to provide circumferential laser irradiation as well as endoscopic coagulation of tubular esophagus tissue for clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.