ArticleMedical physics2023
Interleaved signal multiplexing readout in depth encoding Prism-PET detectors.
Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Multi-Input Interaction Positioning and Signal Demultiplexing With Deep Learning in Semi-Monolithic Detectors.IEEE transactions on radiation and plasma medical sciences · 2026Article
- Improved Edge Pixel Resolution in Modular PET Detectors with Partly Segmented Light Guides.Sensors (Basel, Switzerland) · 2025Article
- High-resolution motion compensation for brain PET imaging using real-time electromagnetic motion tracking.Medical physics · 2025Article
- Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.Medical physics · 2024Article
- A conformal TOF-DOI Prism-PET prototype scanner for high-resolution quantitative neuroimaging.Medical physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundGiven the large number of readout pixels in clinical positron emission tomography (PET) scanners, signal multiplexing is an indispensable feature to reduce scanner complexity, power consumption, heat output, and cost. PURPOSE: In this paper, we introduce interleaved multiplexing (iMux) scheme that utilizes the characteristic light-sharing pattern of depth-encoding Prism-PET detector modules with single-ended readout.
methodsIn the iMux readout, four anodes from every other silicon photomultiplier (SiPM) pixels across rows and columns, which overlap with four distinct light guides, are connected to the same application-specific integrated circuit (ASIC) channel. The 4-to-1 coupled Prism-PET detector module was used which consisted of a 16 × 16 array of 1.5 × 1.5 × 20 mm
resultsThe measured flood histograms, using the decoded energy signals from our deep learning-based demultiplexing architecture, achieved perfect crystal identification of events with negligible decoding error. The average energy, DOI, and timing resolutions were 9.6 ± 1.5%, 2.9 ± 0.9 mm, and 266 ± 19 ps for non-multiplexed readout and 10.3 ± 1.6%, 2.8 ± 0.8 mm, and 311 ± 28 ps for multiplexed readout, respectively.
conclusionsOur proposed iMux scheme improves on the already cost-effective and high-resolution Prism-PET detector module and provides 16-to-1 crystal-to-readout multiplexing without appreciable performance degradation. Also, only four SiPM pixels are shorted together in the 8 × 8 array to achieve 4-to-1 pixel-to-readout multiplexing, resulting in lower capacitance per multiplexed channel.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.