Evidence map›Paper›PMID 37189531›Full record

ArticleDiagnostics (Basel, Switzerland)2023

AI-Based CXR First Reading: Current Limitations to Ensure Practical Value.

Yuriy Vasilev, Anton Vladzymyrskyy, Olga Omelyanskaya, Ivan Blokhin, Yury Kirpichev, Kirill Arzamasov

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Quality control system for patient positioning and filling in meta-information for chest X-ray examinations.International journal of computer assisted radiology and surgery · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuriy VasilevState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.
Anton VladzymyrskyyState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.
Olga OmelyanskayaState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.
Ivan BlokhinState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.ORCID 0000-0002-2681-9378
Yury KirpichevState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.
Kirill ArzamasovState Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Petrovka Street, 24, Building 1, 127051 Moscow, Russia.ORCID 0000-0001-7786-0349

Funding

"Moscow Center for Innovative Technologies in Healthcare" 122112400040-1
6 · The paper itself

Abstract

We performed a multicenter external evaluation of the practical and clinical efficacy of a commercial AI algorithm for chest X-ray (CXR) analysis (Lunit INSIGHT CXR). A retrospective evaluation was performed with a multi-reader study. For a prospective evaluation, the AI model was run on CXR studies; the results were compared to the reports of 226 radiologists. In the multi-reader study, the area under the curve (AUC), sensitivity, and specificity of the AI were 0.94 (CI95%: 0.87-1.0), 0.9 (CI95%: 0.79-1.0), and 0.89 (CI95%: 0.79-0.98); the AUC, sensitivity, and specificity of the radiologists were 0.97 (CI95%: 0.94-1.0), 0.9 (CI95%: 0.79-1.0), and 0.95 (CI95%: 0.89-1.0). In most regions of the ROC curve, the AI performed a little worse or at the same level as an average human reader. The McNemar test showed no statistically significant differences between AI and radiologists. In the prospective study with 4752 cases, the AUC, sensitivity, and specificity of the AI were 0.84 (CI95%: 0.82-0.86), 0.77 (CI95%: 0.73-0.80), and 0.81 (CI95%: 0.80-0.82). Lower accuracy values obtained during the prospective validation were mainly associated with false-positive findings considered by experts to be clinically insignificant and the false-negative omission of human-reported "opacity", "nodule", and calcification. In a large-scale prospective validation of the commercial AI algorithm in clinical practice, lower sensitivity and specificity values were obtained compared to the prior retrospective evaluation of the data of the same population.

Indexed as

AI for chest X-ray first readingexternal validationlocal test setprospective validation

Identifiers

PMID37189531
PMCPMC10138086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.