Observational studyScientific reports2023
Occupational radiation exposure to the lens of the eyes and its protection during endoscopic retrograde cholangiopancreatography.
Observational study in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 26 citations in OpenAlex.
- Robotic-Assisted Bile Duct Cannulation During Endoscopic Retrograde Cholangiopancreatography: A Randomised Controlled Crossover Animal Study.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026Article
- Cholangioscopy-assisted ERCP reduces radiation exposure in treating choledocholithiasis: a retrospective IPTW-adjusted cohort study.Frontiers in medicine · 2026Article
- Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy.Radiation protection dosimetry · 2025Article
- Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy.Journal of radiation research · 2025Article
- 'TLDetect': AI-Based Application for Detection and Correction of Anomalous TLD Glow Curves.Sensors (Basel, Switzerland) · 2024Article
- Real time eye dose reduction in fluoroscopy with auditory and visual feedback dosimeter through swine model experiments.Scientific reports · 2024Article
- Effect of backscatter radiation on the occupational eye-lens dose.Journal of radiation research · 2024Article
- Managing radiation safety and protection in gastroenterology in Japan: insights from the REX-GI study.Journal of gastroenterology · 2024Review
- Effect of radioprotective curtain length on the scattered dose rate distribution and endoscopist eye lens dose with an over-couch fluoroscopy system.Physical and engineering sciences in medicine · 2024Article
- Radiation doses of medical radiation workers performing low-dose-rate brachytherapy withOral radiology · 2024Article
- Patient Radiation Exposure during Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Surgically Altered Anatomy (with Video).Diagnostics (Basel, Switzerland) · 2024Article
- Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study.Diagnostics (Basel, Switzerland) · 2023Article
- Scatter Radiation Distribution to Radiographers, Nearby Patients and Caretakers during Portable and Pediatric Radiography Examinations.Bioengineering (Basel, Switzerland) · 2023Article
- Artificial Neural Network-based Model for Predicting Cardiologists' Over-apron Dose in CATHLABs.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors at 6 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to examine occupational radiation exposure to the lens of the eyes during endoscopic retrograde cholangiopancreatography (ERCP). In this multicenter, prospective, observational cohort study, we collected data regarding occupational radiation exposure to the lens of the eyes during ERCP. We measured radiation exposure of patients and examined its correlation with occupational exposure. In dosimetrically-measured ERCPs (n = 631), the median air kerma at the patient entrance reference point, air kerma-area product, and fluoroscopy time were 49.6 mGy, 13.5 Gycm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.