ArticleCureus2023
Reducing Gadolinium Exposure in Patients Undergoing Monitoring for Meningiomas.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Comparative Evaluation of Lower Gadolinium Doses for MR Imaging of Meningiomas: How Low Can We Go?AJNR. American journal of neuroradiology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Due to the non-malignant and slow-growing nature of many meningiomas, surveillance with serial magnetic resonance imaging (MRI) serves as an acceptable management plan. However, repeated imaging with gold-standard contrast-based studies may lead to contrast-associated adverse effects. Non-gadolinium T2 sequences may serve as a suitable alternative without the risk of adverse effects of contrast. Thus, this study sought to investigate the agreement between post-contrast T1 and non-gadolinium T2 MRI sequences in the measurement of meningioma growth. Methodology The Virginia Commonwealth University School of Medicine (VCU SOM) brain tumor database was used to create a cohort of meningioma patients and determine the number of patients who had T1 post-contrast imaging accompanied by readily measurable imaging from either T2 fast spin echo (FSE) or T2 fluid-attenuated inversion recovery (FLAIR) sequences. Measurements of the largest axial and perpendicular diameters of each tumor were conducted by two independent observers using T1 post-contrast, T2 FSE, and T2 FLAIR imaging series. Lin's concordance correlation coefficient (CCC) was calculated to assess inter-rater reliability between observers and agreement between measurements of tumor diameter among the different imaging sequences. Results In total, 33 patients (average age = 72.1 ± 12.9 years, 90% female) with meningiomas were extracted from our database, with 22 (66.7%) undergoing T1 post-contrast imaging accompanied with readily measurable imaging from T2 FSE and/or T2 FLAIR sequences. The inter-rater reliability between the measurements of T1 axial and perpendicular diameters was 0.96 (95% confidence interval (CI) = 0.92-0.98) and 0.92 (95% CI = 0.83-0.97), respectively. The inter-rater reliability between the measurements of T2 axial perpendicular diameters was 0.93 (95% = CI 0.92-0.97) and 0.89 (95% CI = 0.74-0.95), respectively. The agreements between the measurement of T1 and T2 FSE axial diameter by each observer were 0.97 (95% CI = 0.93-0.98) and 0.92 (95% CI = 0.81-0.97). The agreements between the measurements of T1 and T2 FSE perpendicular diameter measurements by each observer were 0.98 (95% CI = 0.95-0.99) and 0.88 (95% CI = 0.73-0.95). Conclusions Two-thirds of our patients had meningiomas that were readily measurable on either T2 FSE or T2 FLAIR sequences. Additionally, there was excellent inter-rater reliability between the observers in our study as well as an agreement between individual measurements of T1 post-contrast and T2 FSE tumor diameters. These findings suggest that T2 FSE may serve as a safe and similarly effective surveillance method for the long-term management of meningioma patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.