Evidence map›Paper›PMID 37187412›Full record

ArticleJournal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy2023

Clinical evaluation of anterior nasal cavity swab specimens by a rapid antigen test using a GLINE-2019-nCoV Ag Kit to diagnose COVID-19.

Kana Ogane, Kazuo Imai, Yuta Orihara, Masahiro Kodana, Mariko Tezuka, Nanako Matsuzaki, Rina Takahashi, Shintaro Ichimura, Mieko Tokano, Jun Sakai and 3 more

Open access · bronzeAbstract read
In one paragraph

Article in Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Kana OganeDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Kazuo ImaiDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan. Electronic address: k_imai@saitama-med.ac.jp.
Yuta OriharaDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Masahiro KodanaDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Mariko TezukaDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Nanako MatsuzakiDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Rina TakahashiDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Shintaro IchimuraDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Mieko TokanoDepartment of Infectious Disease and Infection Control, Saitama Medical University, Saitama, Japan.
Jun SakaiDepartment of Infectious Disease and Infection Control, Saitama Medical University, Saitama, Japan.
Norihito TarumotoDepartment of Infectious Disease and Infection Control, Saitama Medical University, Saitama, Japan.
Shigefumi MaesakiDepartment of Infectious Disease and Infection Control, Saitama Medical University, Saitama, Japan.
Maeda TakuyaDepartment of Clinical Laboratory, Saitama Medical University Hospital, Saitama, Japan.
Saitama Medical University Hospital · JPSaitama Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The promising diagnostic performance of rapid antigen tests (RATs) using non-invasive anterior nasal (AN) swab specimens to diagnose COVID-19 has been reported. A large number of RATs are commercially available; however, the careful assessment of RATs is essential prior to their implementation in clinical practice. We evaluated the clinical performance of the GLINE-2019-nCoV Ag Kit as a RAT using AN swabs in a prospective, blinded study. Adult patients who visited outpatient departments and received SARS-CoV-2 tests between August 16 and September 8, 2022, were eligible for this study. Patients who were aged under 18 years and patients without appropriate specimens were excluded. Two sets of AN and nasopharyngeal (NP) swabs were collected from all patients. Each set of specimens was tested by the RAT and quantitative reverse-transcription polymerase chain reaction (RT-qPCR). Of the 138 recruited patients, 84 were positive and 54 were negative by RT-qPCR using NP swabs. The positive agreement rate between RT-qPCR using NP swabs and RAT using AN swabs was 78.6% (95% confidence interval [CI], 68.3%-86.8%), the negative agreement rate was 98.1% (95% CI, 90.1%-99.9%), and the overall agreement rate was 86.2% (95% CI, 79.3%-91.5%), with a κ coefficient of 0.73. The positive agreement rate in the early phase (≤3 days from symptom onset) was >80%, but this fell to 50% in the late phase (≥4 days). This study demonstrates that the GLINE-2019-nCoV Ag Kit using AN swabs has good clinical performance and might be a reliable alternative method for diagnosing COVID-19.

Indexed as

COVID-19SARS-CoV-2HumansImmunologic TestsNasal CavityNasopharynxProspective StudiesSensitivity and SpecificityAnterior nasal swabCOVID-19Rapid antigen testRT-qPCRSARS-CoV-2

Identifiers

PMID37187412
PMCPMC10182653
OpenAlexW4376604554

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.