Evidence map›Paper›PMID 37187153›Full record

ArticleJournal of the mechanical behavior of biomedical materials2023

A finite porous-viscoelastic model capturing mechanical behavior of human cervix under multi-step spherical indentation.

Lei Shi, Kristin Myers

Open access · greenAbstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Nonmonotonic rate-dependent adhesion of hydrogels.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Equilibrium Mechanical Properties of the Nonhuman Primate Cervix.Journal of biomechanical engineering · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Lei ShiDepartment of Mechanical Engineering, Columbia University, 500 W 120th St, MC 4703, New York, 10027, NY, USA.
Kristin MyersDepartment of Mechanical Engineering, Columbia University, 500 W 120th St, MC 4703, New York, 10027, NY, USA. Electronic address: kmm2233@columbia.edu.
Columbia University · US

Funding

Mechanisms by which steroid hormones modulate cervical extracellular matrix structure and function during pregnancy and provide therapeutic protection against preterm birthR01HD088481 · NICHD · UT SOUTHWESTERN MEDICAL CENTER · PI MAHENDROO, MALA S., MYERS, KRISTIN MARIE · 2016 to 2020
$1.8M
A Computational Framework for the Clinical Evaluation of the Soft Tissue Mechanics in PregnancyR01HD091153 · NICHD · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI MYERS, KRISTIN MARIE · 2017 to 2021
$1.6M
NICHD NIH HHS R01 HD088481NICHD NIH HHS R01 HD091153
6 · The paper itself

Abstract

The cervix is a soft tissue exhibiting time-dependent behavior under mechanical loads. The cervix is a vital mechanical barrier to protect the growing fetus. The remodeling of the cervical tissue, characterized by an increase in time-dependent material properties, is necessary for a safe parturition. The failure of its mechanical function and accelerated tissue remodeling is hypothesized to lead to preterm birth, which is birth before 37 weeks of gestation. To understand the mechanism of the time-dependent behavior of the cervix under compressive states, we employ a porous-viscoelastic material model to describe a set of spherical indentation tests performed on nonpregnant and term pregnant tissue. A genetic algorithm-based inverse finite element analysis is used to fit the force-relaxation data by optimizing the material parameters, and the statistical analysis of the optimized material parameters is conducted on different sample groups. The force response is captured well using the porous-viscoelastic model. The indentation force-relaxation of the cervix is explained by the porous effects and the intrinsic viscoelastic properties of the extracellular matrix (ECM) microstructure. The hydraulic permeability obtained from the inverse finite element analysis agrees with the trend of the value directly measured previously by our group. The nonpregnant samples are found significantly more permeable than the pregnant samples. Within nonpregnant samples, the posterior internal os is found significantly less permeable than the anterior and posterior external os. The proposed model exhibits the superior capability to capture the force-relaxation response of the cervix under indentation, as compared to the conventional quasi-linear viscoelastic framework (range of r

Indexed as

Cervix UteriPremature BirthElasticityFemaleFinite Element AnalysisHumansInfant, NewbornMechanical PhenomenaParturitionPorosityPregnancyStress, MechanicalViscosityCervix biomechanicsFinite element analysisHydraulic permeabilityPoroelasticitySpherical indentation

Identifiers

PMID37187153
PMCPMC10330483
OpenAlexW4367678517

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.