Evidence map›Paper›PMID 37185943›Full record

ArticleScientific reports2023

Spectral cardiac CT in acute stroke patients.

Naomi Larsen, Friederike Austein, Tristan Klintz, Graeme Campbell, Sam Sedaghat, Schekeb Aludin, Domagoj Schunk, Marcus Both, Olav Jansen, Patrick Langguth

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Naomi LarsenDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany. naomi.larsen@uksh.de.ORCID 0000-0002-8782-8278
Friederike AusteinDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Tristan KlintzDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Graeme CampbellPhilips Healthcare, Clinical Science, Philips GmbH Market DACH, Röntgenstr. 22, 22335, Hamburg, Germany.
Sam SedaghatDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Schekeb AludinDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Domagoj SchunkInterdisciplinary Emergency Department, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Marcus BothDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Olav JansenDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
Patrick LangguthDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Arnold-Heller-Str. 3, 24105, Kiel, Germany.ORCID 0000-0001-7138-7415
University Hospital Schleswig-Holstein · DEPhilips (Germany) · DEUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac CT obtained in acute ischemic stroke patients can facilitate timely detection of cardiac sources of embolism and guide secondary prevention strategies. Spectral CT exploiting the simultaneous acquisition of separate higher-energy and lower-energy photon spectrum datasets has the potential to improve contrast between thrombi and cardiac structures. This study aimed to investigate the diagnostic value of spectral cardiac CT compared to conventional CT for the detection of cardiac thrombi in acute stroke patients. Patients with acute ischemic stroke undergoing spectral cardiac CT were retrospectively included. Conventional CT images, virtual 55 keV monoenergetic (monoE55), z-effective (zeff), and iodine density images were evaluated for the presence of thrombi. Diagnostic certainty was rated on a 5-point Likert scale. Contrast ratios were calculated for all reconstructions. 63 patients with 20 thrombi were included. Four thrombi were missed on conventional images but detected on spectral reconstructions. MonoE55 achieved the highest scores for diagnostic certainty. Contrast ratios were highest on iodine density images, followed by monoE55, conventional and zeff (p < 0.005). Spectral cardiac CT adds diagnostic benefit for the detection of intra-cardiac thrombi in acute ischemic stroke patients compared to conventional CT.

Indexed as

IodineIschemic StrokeStrokeHumansRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSignal-To-Noise RatioTomography, X-Ray ComputedIodine

Identifiers

PMID37185943
PMCPMC10130047
OpenAlexW4366997488

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.