Evidence map›Paper›PMID 37185670›Full record

ArticleClinical neuroradiology2023

Fragmentation of Hydrophilic Guidewire Coatings During Neuroendovascular Therapy.

Rasmus Holmboe Dahl, René Wugt Larsen, Esben Thormann, Goetz Benndorf

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical neuroradiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Rasmus Holmboe DahlDepartment of Radiology, University Hospital Rigshospitalet, Copenhagen, Denmark.ORCID http://orcid.org/0000-0002-2014-7400
René Wugt LarsenDepartment of Chemistry, Technical University of Denmark, Kongens Lyngby, Denmark.ORCID http://orcid.org/0000-0003-2983-6795
Esben ThormannDepartment of Chemistry, Technical University of Denmark, Kongens Lyngby, Denmark.
Goetz BenndorfDepartment of Radiology, University Hospital Rigshospitalet, Copenhagen, Denmark. bnndrf@gmail.com.ORCID http://orcid.org/0000-0002-2364-3493
Technical University of Denmark · DKBaylor College of Medicine · USHvidovre Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCerebral polymer coating embolism from intravascular devices may cause serious complications after endovascular therapy (EVT) for neurovascular diseases. Although polymer fragments are often created during endovascular procedures, exact mechanisms of their formation, especially if of small size, are largely unknown.

methodsIn this study eight microguidewires (Asahi Chikai 200 cm (Asahi Intecc, Aichi, Japan), Asahi Chikai Black (Asahi Intecc), Fathom™ (Boston Scientific, Marlborough, MA, USA), Hybrid (Balt Extrusion, Montmorency, France), Radifocus® Guide Wire GT (Terumo, Leuven, Belgium), Synchro

resultsBackloading caused damage to the coating of all microguidewires especially when the main body of the guidewires was bent in front of the insertion tool. All studied microguidewires produced microscopic filamentous and/or band-like coating fragments. Few larger irregular fragments were observed, but also very small fragments measuring 1-3 µm in diameter were found. Spectroscopic measurements of polymer fragments and microguidewires identified various polymers.

conclusionBackloading of polymer-coated microguidewires during EVT should be minimized if possible. More stable hydrophilic coatings on microguidewires and less traumatic insertion tools are desirable.

Indexed as

CatheterizationEndovascular ProceduresCoated Materials, BiocompatibleFranceHumansJapanPolymersCoated Materials, BiocompatiblePolymersAttenuated total reflection Fourier transform infrared spectroscopyCerebral polymer embolismDelaminationHydrophilic polymerMicroguidewire coatingPolytetrafluoroethylene

Identifiers

PMID37185670
OpenAlexW4366976917

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.