Evidence map›Paper›PMID 37185506›Full record

ArticleBiosensors2023

Biomimetic Electrochemical Sensors Based on Core-Shell Imprinted Polymers for Targeted Sunset Yellow Estimation in Environmental Samples.

Sumeet Malik, Adnan Khan, Hamayun Khan, Gul Rahman, Nauman Ali, Sabir Khan, Maria Del Pilar Taboada Sotomayor

Abstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sumeet MalikInstitute of Chemical Sciences, University of Peshawar, Khyber Pakhtunkhwa 25120, Pakistan.ORCID 0000-0002-7937-0869
Adnan KhanInstitute of Chemical Sciences, University of Peshawar, Khyber Pakhtunkhwa 25120, Pakistan.
Hamayun KhanDepartment of Chemistry, Islamia College Peshawar, Khyber Pakhtunkhwa 25120, Pakistan.
Gul RahmanInstitute of Chemical Sciences, University of Peshawar, Khyber Pakhtunkhwa 25120, Pakistan.ORCID 0000-0003-1335-146X
Nauman AliInstitute of Chemical Sciences, University of Peshawar, Khyber Pakhtunkhwa 25120, Pakistan.ORCID 0000-0002-7485-6843
Sabir KhanChemistry Institute, São Paulo State University (UNESP), Araraquara 14801-900, SP, Brazil.
Maria Del Pilar Taboada SotomayorChemistry Institute, São Paulo State University (UNESP), Araraquara 14801-900, SP, Brazil.ORCID 0000-0002-6173-7888

Funding

Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica PE501080434-2022-PROCIENCIANational Council for Scientific and Technological Development 301728/2019-4National University of Engineering FC-27-PF-20222
6 · The paper itself

Abstract

Magnetic molecularly imprinted polymers (MMIPs) contain the predesigned specialized recognition capability that can be chosen to build credible functional materials, that are easy to handle and have a good degree of specificity. Hence, the given piece of work is intended to design a novel electrochemical sensor incorporating magnetite-based molecularly imprinted polymers. The building materials consisted of a cross-linker (EGDMA), reaction-initiator (AIBN), monomer (methylene succinic acid-MSA), and template molecule (Sunset Yellow-SY dye). MMIPs exhibited a diameter of 57 nm with an irregular shape due to the presence of cavities based on SEM analysis. XRD patterns exhibited crystallinity, as well as amorphous peaks that are attributed to polymeric and non-polymeric frameworks of MMIPs. The crystallite size of the MMIPs from XRD analysis was found to be 16.28 nm based on the Debye-Scherrer's equation. Meanwhile, the FTIR bands showed the synthesis of MMIPs using monomer and methylene succinic acid. The sorption data at the optimized operating conditions (pH 2, sorbent dosage 3 mg, time 18 min) showed the highest sorption capacity of 40 mg/g. The obtained data best fitted to the Langmuir sorption isotherm and followed the pseudo-second-order kinetics. The magneto-sensors were applied for ultrasensitive, rapid, and simple sensing of SY dye. The electrochemical experiments were run at the operating condition range of (scan rate 10-50 mV/s, tads 0-120 s, pH 5-9, potential range 1-1.5 V for CV and 1-1.3 V for SWAdASV). The linear range of detection was set to 1.51 × 10

Indexed as

Molecular ImprintingPolymersAzo CompoundsBiomimeticsMolecularly Imprinted PolymersSuccinic Acid6-hydroxy-5-((p- sulfophenyl)azo)-2-naphthalenesulfonic acid disodium saltAzo CompoundsMolecularly Imprinted PolymersPolymersSuccinic Acidadsorptionelectrochemical sensorsmolecularly imprinted polymersprecipitation polymerizationsunset yellow dye

Identifiers

PMID37185506
PMCPMC10136464

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.