Evidence map›Paper›PMID 37183802›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2023

A Clinical Study of 50 Partially Edentulous Patients with Fixed Partial Denture Restorations to Compare Clinical Parameters and Changes in Gingival Sulcus Width After Displacement with 2 Different Gingival Retraction Cord Materials (Cotton and Polymer).

Lakshya Kumar, Khurshid A Mattoo, Shailesh Jain, Imran Khalid, Mohammad Z Kota, Fawaz A H Baig, Mohammed Ibrahim, Mukhatar A Javali, Mohasin A Khader, Masroor A Kanji

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Comparative Evaluation of Dimensional and Occlusal Accuracy of Non-Working Antagonist Casts: A Study on Different Impression Materials and 3D Printing.Medical science monitor : international medical journal of experimental and clinical research · 2023
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Lakshya KumarDepartment of Prosthodontics, King George Dental College, King George's Medical University (KGMU), Lucknow, India.
Khurshid A MattooDepartment of Prosthodontics, Subharti Dental College, Swami Vivekananda Subharti University, Meerut, India.ORCID 0000-0003-1191-437X
Shailesh JainDepartment of Prosthodontics, Subharti Dental College, Swami Vivekananda Subharti University, Meerut, India.ORCID 0000-0002-3510-6791
Imran KhalidDepartment of Oral and Maxillofacial Surgery, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Mohammad Z KotaDepartment of Oral and Maxillofacial Surgery, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Fawaz A H BaigDepartment of Oral and Maxillofacial Surgery, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0001-8096-4683
Mohammed IbrahimDepartment of Oral and Maxillofacial Surgery, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Mukhatar A JavaliDepartment/Division of Periodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Mohasin A KhaderDepartment/Division of Periodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Masroor A KanjiDepartment of Prosthodontics, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0003-2959-8344
King Khalid University · SAJazan University · SAKing George's Medical University · INSharda University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND The present study aimed to compare the clinical performance and gingival sulcus width changes in partially edentulous patients using cotton and polymer gingival retraction cords. MATERIAL AND METHODS Fifty partially edentulous patients were divided into 2 groups (Gp C and Gp P) and were subjected to single crown/fixed partial denture treatment. Clinical parameters, including plaque index scores, placement time, and hemorrhage control scores, were assessed. Gingival sulcus width changes before and after retraction were evaluated using individual type 4 dental stone dies observed under an optical microscope. Statistical analysis was performed using dependent/independent t tests. RESULTS The mean placement time, hemorrhage control time, and hemorrhagic scores were lower in Gp P than in Gp C, indicating better clinical performance of polymer-based retraction cord. Both groups showed an increase in sulcus width after retraction, but Gp P had a significantly higher sulcus width (690.03±45.37) compared to Gp C (471.38±28.13). The mean difference in sulcus width between baseline and after retraction was also significantly higher in Gp P (525.84 micrometers) than in Gp C (309.11 micrometers). CONCLUSIONS The present study shows that polymer-based cords produce more sulcus width and have better clinical performance compared to cotton-based gingival retraction cords. These results suggest that the use of polymer-based retraction cords can improve the quality of dental impressions in partially edentulous patients.

Indexed as

GingivaPolymersCrownsHemorrhageHumansPolymers

Identifiers

PMID37183802
PMCPMC10152903
OpenAlexW4364361549

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.