Evidence map›Paper›PMID 37180455›Full record

ArticleMicrosystems & nanoengineering2023

Highly conformable chip-in-foil implants for neural applications.

Thomas Stieglitz, Calogero Gueli, Julien Martens, Niklas Floto, Max Eickenscheidt, Markus Sporer, Maurits Ortmanns

Open access · goldAbstract read
In one paragraph

Article in Microsystems & nanoengineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Thomas StieglitzLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany.ORCID 0000-0002-7349-4254
Calogero GueliLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany.ORCID 0000-0003-1483-3065
Julien MartensLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany.ORCID 0000-0003-4668-1860
Niklas FlotoLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany.
Max EickenscheidtLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany.ORCID 0000-0002-8348-7269
Markus SporerInstitute of Microelectronics, University of Ulm, D-89081 Ulm, Germany.ORCID 0000-0002-0328-653X
Maurits OrtmannsInstitute of Microelectronics, University of Ulm, D-89081 Ulm, Germany.ORCID 0000-0002-3547-1596
University of Freiburg · DEUniversität Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Demands for neural interfaces around functionality, high spatial resolution, and longevity have recently increased. These requirements can be met with sophisticated silicon-based integrated circuits. Embedding miniaturized dice in flexible polymer substrates significantly improves their adaptation to the mechanical environment in the body, thus improving the systems' structural biocompatibility and ability to cover larger areas of the brain. This work addresses the main challenges in developing a hybrid chip-in-foil neural implant. Assessments considered (1) the mechanical compliance to the recipient tissue that allows a long-term application and (2) the suitable design that allows the implant's scaling and modular adaptation of chip arrangement. Finite element model studies were performed to identify design rules regarding die geometry, interconnect routing, and positions for contact pads on dice. Providing edge fillets in the die base shape proved an effective measure to improve die-substrate integrity and increase the area available for contact pads. Furthermore, routing of interconnects in the immediate vicinity of die corners should be avoided, as the substrate in these areas is prone to mechanical stress concentration. Contact pads on dice should be placed with a clearance from the die rim to avoid delamination when the implant conforms to a curvilinear body. A microfabrication process was developed to transfer, align, and electrically interconnect multiple dice into conformable polyimide-based substrates. The process enabled arbitrary die shape and size over independent target positions on the conformable substrate based on the die position on the fabrication wafer.

Indexed as

Bioelectronic DevicesChip-in-FoilConformable SubstrateHybrid ImplantsImplantable Flexible SystemMicrofabricationPolyimide

Identifiers

PMID37180455
PMCPMC10167239
OpenAlexW4375945583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.