Evidence map›Paper›PMID 37179983›Full record

ArticleSovremennye tekhnologii v meditsine2022

An Algorithm for Automatic Generation and Evaluation of Leaflet Apparatus Models for Heart Valve Prostheses.

P S Onischenko, K Yu Klyshnikov, Е А Ovcharenko, L S Barbarash

Abstract read
In one paragraph

Article in Sovremennye tekhnologii v meditsine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

P S OnischenkoJunior Researcher, Laboratory of New Biomaterials, Department of Experimental Medicine; Research Institute for Complex Issues of Cardiovascular Diseases, 6 Sosnovy Blvd, Kemerovo, 650002, Russia.
K Yu KlyshnikovResearcher, Laboratory of New Biomaterials, Department of Experimental Medicine; Research Institute for Complex Issues of Cardiovascular Diseases, 6 Sosnovy Blvd, Kemerovo, 650002, Russia.
Е А OvcharenkoHead of the Laboratory of New Biomaterials, Department of Experimental Medicine; Research Institute for Complex Issues of Cardiovascular Diseases, 6 Sosnovy Blvd, Kemerovo, 650002, Russia.
L S BarbarashProfessor, Academician of the Russian Academy of Sciences, Chief Researcher; Research Institute for Complex Issues of Cardiovascular Diseases, 6 Sosnovy Blvd, Kemerovo, 650002, Russia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Materials and Methods: The suggested algorithm consists of three blocks: "Generator", "Modeling", "Analysis". The first block creates a three-dimensional model of the leaflet apparatus using the specified parameters (height, radius, thickness, degree of "sagging", angle of the free edge deviation). Numerical simulation of the apparatus functioning is further performed using the finite element method. Then, the statistical analysis of the von Mises stresses is done and the opening area of the design in question is calculated.Verification was performed by comparing quantitatively the lumen areas of the leaflet apparatus in the open state, obtained from the literature data for the Trifecta bioprosthesis (19, 21, and 23 mm in diameter), with the results of the described algorithm operation. Results: The verification of the algorithm has demonstrated the following deviations in the lumen area in the open state: 2.85% for 19 mm, 14.81% for 21 mm, and 23.17% for 23 mm models. This difference is due to the choice of the model material (no data could be found on the physical and mechanical properties of the pericardium used for the fabrication of the Trifecta bioprostheses).The generation of a large number of designs (n=1517) without fixation of certain geometry parameters has shown that thickness of the leaflet apparatus makes the greatest contribution to the degree of opening; its dependence on the thickness and arising peak von Mises stresses has been demonstrated. Of the valvular models obtained, 278 showed the opening degree greater than 80% and maximum peak von Mises stresses below 4 MPa for the proposed model of the pericardium, which is 65% below the ultimate strength of the material.Out of 278 leaflet models, 3 "optimal" designs were selected meeting the diameter criteria of 19, 21, and 23 mm. The loss index for them was 0.24, 0.19, 0.20 with the opening degrees of 88.28, 84.48, 88.12%, and maximum peak von Mises stresses of 3.62, 1.21, 1.87 MPa, respectively. Conclusion: The developed algorithm makes it possible to automatically generate three-dimensional models of the leaflet apparatus, numerically simulate the opening process using the finite element method, statistically analyze the results obtained, and calculate the lumen area. The algorithm was verified based on the data for the Trifecta bioprosthesis of three standard sizes. The presented algorithm can be used both for the research and development of various designs and for obtaining "optimal" models of sash devices.

Indexed as

Heart Valve ProsthesisAlgorithmsModels, CardiovascularProsthesis DesignProsthesis Implantationalgorithm for generation and evaluation of leaflet apparatusesheart valve prosthesissimulation

Identifiers

PMID37179983
PMCPMC10171043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.