Evidence map›Paper›PMID 37179453›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2023

A Scanning Electron Microscopy Study Comparing 3 Obturation Techniques to Seal Dentin to Root Canal Bioceramic Sealer in 30 Freshly Extracted Mandibular Second Premolars.

Nuha S Alghamdi, Ruaa A Alamoudi, Suheel Manzoor Baba, Khurshid Mattoo, Rushdiyah H Abu Hawi, Wejdan Nasser Ali, Nouf Mohammed Hassan Almadhlami, Alya Mohammed Ahmed Lahiq

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Impact of Margin Type and Material Choice on Stress Distribution in Endocrown Restorations: A 3D Finite Element Study.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  4. Article
  5. Article
  6. Comparative Evaluation of Dimensional and Occlusal Accuracy of Non-Working Antagonist Casts: A Study on Different Impression Materials and 3D Printing.Medical science monitor : international medical journal of experimental and clinical research · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Nuha S AlghamdiDepartment of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Ruaa A AlamoudiEndodontic Department, Faculty of Dentistry, King Abdul-Aziz University, Jeddah, Saudi Arabia.ORCID 0000-0003-4973-2686
Suheel Manzoor BabaDepartment of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-9729-883X
Khurshid MattooProsthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
Rushdiyah H Abu HawiDental Graduates, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Wejdan Nasser AliDental Graduates, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Nouf Mohammed Hassan AlmadhlamiDental Graduates, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Alya Mohammed Ahmed LahiqDental Graduates, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
King Khalid University · SAJazan University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Obturation is a crucial step in dentistry, involving the filling and sealing of a prepared root canal with sealer and core material to prevent bacterial invasion and ensure successful treatment. This study employed scanning electron microscopy to compare the effectiveness of 3 obturation techniques - single-cone technique (SCT), cold lateral compaction technique (CLCT), and continuous-wave technique (CWT) - in sealing dentin to recently introduced root canal bioceramic sealer in 30 extracted mandibular second premolars. The goal was to determine the optimal technique for minimizing gaps at the sealer-dentin interface. MATERIAL AND METHODS Thirty premolars were divided into 3 groups (n=10 each) based on obturation technique: SCT, CLCT, and CWT. All groups used CeraSeal bioceramic root canal sealer. Root samples were sectioned at apical, middle, and coronal thirds, and high-resolution scanning electron microscopy was performed to measure marginal/internal gaps. Data were analyzed using one-way ANOVA and Tukey range test, with P≤0.05 considered statistically significant. RESULTS CWT showed fewer voids at all levels, with non-significant differences within a technique. Among the techniques, SCT had the largest mean gaps at all levels [apical (5.43±0.16), middle (5.28±0.20), coronal (5.73±0.24)], while CWT had the smallest mean gaps [apical (3.02±0.19), middle (2.95±0.14), coronal (2.76±0.15)]. The differences in means between techniques were statistically significant (P≤0.05). CONCLUSIONS CWT obturation with CeraSeal root canal sealer produces fewer marginal gaps at the sealer-dentin interface.

Indexed as

Root Canal Filling MaterialsBicuspidDental Pulp CavityDentinMicroscopy, Electron, ScanningRoot Canal ObturationRoot Canal Filling Materials

Identifiers

PMID37179453
PMCPMC10214875
OpenAlexW4367317732

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.