Evidence map›Paper›PMID 37178419›Full record

ArticleThe international journal of cardiovascular imaging2023

Assessment of right ventricular structure and systolic function in amateur marathon runners using three-dimensional speckle tracking echocardiography.

Shanting Hu, Hebin Zhang, Hui Ma, Cunxin Yang, Peipei Hu, Feng Gao

Open access · hybridAbstract read
In one paragraph

Article in The international journal of cardiovascular imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Shanting HuDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China.
Hebin ZhangDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China.
Hui MaDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China.
Cunxin YangDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China.
Peipei HuDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China.
Feng GaoDepartment of Ultrasonography, Affiliate Hospital of Hangzhou Normal University, Hangzhou, China. z632023@163.com.
Affiliated Hospital of Hangzhou Normal University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prolonged high-intensity endurance exercise has been reported to have adverse effects on the heart, which are further correlated with exercise dose. However, its effect on the right ventricle (RV) of amateur runners is unknown. This study aimed was to evaluate the early right ventricular structure and systolic function of amateur marathon runners by three-dimensional speckle tracking echocardiography (3D-STE), and to further analyze the correlation between relevant parameters and the amount of training. A total of 30 amateur marathon runners (marathon group) and 27 healthy volunteers (control group) were enrolled. Conventional echocardiography combined with 3D-STE was performed in all subjects, and the marathon group was screened by echocardiography a week before a marathon (V1), within 1 h post-marathon (V2), and 4 days post-marathon (V3). RV global longitudinal strain (GLS) and RV end-diastolic volume (EDV) increased significantly in the marathon group compared to the control group (P < 0.05). RV GLS was significantly decreased in the marathon group within 1 h post-marathon (V1: - 26.2 ± 2.5% vs V2: - 23.0 ± 1.6% vs V3: - 25.6 ± 2.6%, P < 0.001). However, there was no significant difference in RV ejection fraction (RVEF) (P > 0.05). The results of the correlation analysis showed that RV EDV and RV end-systolic volume (ESV) were positively correlated with the average training volume (P < 0.001). Multivariate linear regression analysis showed that average training volume was an independent predictor of RV EDV in amateur marathoners (β = 0.642, P < 0.001). The systolic function of the RV was enhanced in amateur marathon runners in the early stage, manifested by an increase in RV EDV. After a long period of high-intensity endurance exercise, RV systolic function will temporarily be reduced. 3D-STE can identify this subclinical change with high sensitivity and provide valuable information to assess the structure and function of RV in amateur marathon runners.

Indexed as

Echocardiography, Three-DimensionalVentricular Dysfunction, RightEchocardiographyExerciseHeart VentriclesHumansMarathon RunningPredictive Value of TestsVentricular Function, RightMarathonRight ventricular functionThree-dimensional speckle tracking echocardiography

Identifiers

PMID37178419
PMCPMC10427556
OpenAlexW4376598153

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.