ArticleSensors (Basel, Switzerland)2023
Miniaturization of an Osmotic Pressure-Based Glucose Sensor for Continuous Intraperitoneal and Subcutaneous Glucose Monitoring by Means of Nanotechnology.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Gut-targeted therapies for type 2 diabetes mellitus: A review.World journal of clinical cases · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
Abstract
The Sencell sensor uses glucose-induced changes in an osmotic pressure chamber for continuous glucose measurement. A final device shall have the size of a grain of rice. The size limiting factor is the piezo-resistive pressure transducers inside the core sensor technology (resulting chamber volume: 70 µL. To achieve the necessary miniaturization, these pressure transducers were replaced by small (4000 × 400 × 150 nm³) nano-granular tunneling resistive (NTR) pressure sensors (chamber volume: 750 nL). For benchmark testing, we filled the miniaturized chamber with bovine serum albumin (BSA, 1 mM) and exposed it repeatedly to distilled water followed by 1 mM BSA solution. Thereafter, we manufactured sensors with glucose testing chemistry (ConcanavalinA/dextran) and investigated sensor performance with dynamic glucose changes between 0 and 300 mg/dL. Evaluation of the miniaturized sensors resulted in reliable pressure changes, both in the BSA benchmark experiment (30-35 mBar) and in the dynamic in vitro continuous glucose test (40-50 mBar). These pressure results were comparable to similar experiments with the previous larger in vitro sensors (30-50 mBar). In conclusion, the NTR pressure sensor technology was successfully employed to reduce the size of the core osmotic pressure chamber by more than 95% without loss in the osmotic pressure signal.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.