Evidence map›Paper›PMID 37177720›Full record

ArticleSensors (Basel, Switzerland)2023

Design and Study of a Reflector-Separated Light Dispersion-Compensated 3D Microscopy System.

Hui Li, Xin Tan, Qingbin Jiao, Yuhang Li, Siqi Liu, Jian Pei, Jiahang Zhang, Wei Zhang, Liang Xu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hui LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Xin TanChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Qingbin JiaoChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Yuhang LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Siqi LiuChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Jian PeiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Jiahang ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Wei ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.
Liang XuChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Beijing 130033, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The secondary-phase grating-based tomographic microscopy system, which is widely used in the biological and life sciences, can observe all the sample multilayer image information simultaneously because it has multifocal points. However, chromatic aberration exists in the grating diffraction, which seriously affects the observation of the image. To correct the chromatic aberration of the tomographic microscope system, this paper proposes a system that adopts blazed gratings and angle-variable reflectors as chromatic aberration correction devices according to the principle of dispersion compensation and Fourier phase-shift theory. A reflector-separated light dispersion-compensated 3D microscopy system is presented to achieve chromatic aberration correction while solving the problem of multilayer image overlap. The theoretical verification and optical design of the system were completed using ZEMAX software. The results show that the proposed system reduced the chromatic aberration of ordinary tomographic microscopy systems by more than 90%, retaining more wavelengths of light information. In addition, the system had a relatively wide range in the color difference compensation element installation position, reducing the difficulty of dispersion compensation element installation. Overall, the results indicate that the proposed system is effective in reducing chromatic aberration in grating diffraction.

Indexed as

dispersion compensationoptical designsecondary-phase gratingtomographic microscopy system

Identifiers

PMID37177720
PMCPMC10181646

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.