Evidence map›Paper›PMID 37177614›Full record

ReviewSensors (Basel, Switzerland)2023

Magnetic Particle Spectroscopy for Point-of-Care: A Review on Recent Advances.

Parsa Yari, Bahareh Rezaei, Clifton Dey, Vinit Kumar Chugh, Naga Venkata Ravi Kumar Veerla, Jian-Ping Wang, Kai Wu

Open access · goldAbstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. DNA Sensor for the Detection ofInternational journal of molecular sciences · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Parsa YariDepartment of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.ORCID 0000-0003-2422-014X
Bahareh RezaeiDepartment of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
Clifton DeyDepartment of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
Vinit Kumar ChughDepartment of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA.ORCID 0000-0001-7818-7811
Naga Venkata Ravi Kumar VeerlaDepartment of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
Jian-Ping WangDepartment of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA.ORCID 0000-0003-2815-6624
Kai WuDepartment of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.ORCID 0000-0002-9444-6112
Texas Tech University · USUniversity of Minnesota · US

Funding

National Institute of Food and Agriculture 2020-67021-31956
6 · The paper itself

Abstract

Since its first report in 2006, magnetic particle spectroscopy (MPS)-based biosensors have flourished over the past decade. Currently, MPS are used for a wide range of applications, such as disease diagnosis, foodborne pathogen detection, etc. In this work, different MPS platforms, such as dual-frequency and mono-frequency driving field designs, were reviewed. MPS combined with multi-functional magnetic nanoparticles (MNPs) have been extensively reported as a versatile platform for the detection of a long list of biomarkers. The surface-functionalized MNPs serve as nanoprobes that specifically bind and label target analytes from liquid samples. Herein, an analysis of the theories and mechanisms that underlie different MPS platforms, which enable the implementation of bioassays based on either volume or surface, was carried out. Furthermore, this review draws attention to some significant MPS platform applications in the biomedical and biological fields. In recent years, different kinds of MPS point-of-care (POC) devices have been reported independently by several groups in the world. Due to the high detection sensitivity, simple assay procedures and low cost per run, the MPS POC devices are expected to become more widespread in the future. In addition, the growth of telemedicine and remote monitoring has created a greater demand for POC devices, as patients are able to receive health assessments and obtain results from the comfort of their own homes. At the end of this review, we comment on the opportunities and challenges for POC devices as well as MPS devices regarding the intensely growing demand for rapid, affordable, high-sensitivity and user-friendly devices.

Indexed as

Biosensing TechniquesPoint-of-Care SystemsHumansMagnetic PhenomenaMagneticsSpectrum Analysisbiosensordisease detectionfood safetymagnetic particle spectroscopypoint-of-caresurface-based assayvolumetric assay

Identifiers

PMID37177614
PMCPMC10181768
OpenAlexW4367626589

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.