ArticleSensors (Basel, Switzerland)2023
A Liquid Metal Temperature Detection System Based on Multi-Node Sapphire Fiber Sensor.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
In order to accurately detect the temperature of molten aluminum and overcome the adverse influence of high temperature and corrosiveness on the sensing results, a temperature detection system based on a multi-node sapphire fiber sensor was proposed and developed. Through the structural parameter design of the fiber sensor, the scheme of utilizing the 0.7 mm diameter fiber and 0.5 mm groove was formulated. Simulation and analysis were carried out to determine the ultrasonic response distribution of the signal passing through the whole fiber sensor. The results indicate that the system is capable of distinguishing test signals from various positions and temperatures. Following the completion of the static calibration, the temperature of the molten aluminum was observed in real-time, and the data of the temperature measurements conducted at the two groove locations were compared. According to the obtained results, the test accuracy was greater than 1 degree Celsius and the temperature test stability was good, laying a solid foundation for the potential development of temperature measurement devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.