Real-Time Evaluation of Time-Domain Pulse Rate Variability Parameters in Different Postures and Breathing Patterns Using Wireless Photoplethysmography Sensor: Towards Remote Healthcare in Low-Resource Communities.

Felipe Pineda-Alpizar, Sergio Arriola-Valverde, Mitzy Vado-Chacón, Diego Sossa-Rojas, Haipeng Liu, Dingchang Zheng

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Felipe Pineda-AlpizarIndustrial Design Engineering Department, Costa Rica Institute of Technology, Cartago 7050, Costa Rica.
Sergio Arriola-ValverdeElectronics Engineering Department, Costa Rica Institute of Technology, Cartago 7050, Costa Rica.ORCID 0000-0003-1155-3076
Mitzy Vado-ChacónRespiratory Therapy Department, Santa Paula University, San Jose 2633, Costa Rica.
Diego Sossa-RojasRespiratory Therapy Department, Santa Paula University, San Jose 2633, Costa Rica.
Haipeng LiuCenter of Intelligent Healthcare, Coventry University, Coventry CV1 5FB, UK.ORCID 0000-0002-4212-2503
Dingchang ZhengCenter of Intelligent Healthcare, Coventry University, Coventry CV1 5FB, UK.ORCID 0000-0001-8077-4548
Instituto Tecnológico de Costa Rica · CRIntelligent Health (United Kingdom) · GBUniversidad Santa Paula · CR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photoplethysmography (PPG) signals have been widely used in evaluating cardiovascular biomarkers, however, there is a lack of in-depth understanding of the remote usage of this technology and its viability for underdeveloped countries. This study aims to quantitatively evaluate the performance of a low-cost wireless PPG device in detecting ultra-short-term time-domain pulse rate variability (PRV) parameters in different postures and breathing patterns. A total of 30 healthy subjects were recruited. ECG and PPG signals were simultaneously recorded in 3 min using miniaturized wearable sensors. Four heart rate variability (HRV) and PRV parameters were extracted from ECG and PPG signals, respectively, and compared using analysis of variance (ANOVA) or Scheirer-Ray-Hare test with post hoc analysis. In addition, the data loss was calculated as the percentage of missing sampling points. Posture did not present statistical differences across the PRV parameters but a statistical difference between indicators was found. Strong variation was found for the RMSSD indicator in the standing posture. The sitting position in both breathing patterns demonstrated the lowest data loss (1.0 ± 0.6 and 1.0 ± 0.7) and the lowest percentage of different factors for all indicators. The usage of commercial PPG and BLE devices can allow the reliable extraction of the PPG signal and PRV indicators in real time.

Indexed as

PhotoplethysmographyPostureElectrocardiographyHealthy VolunteersHeart RateHumansRespirationBluetooth low energy (BLE)embedded systemsheart rate variability (HRV)photoplethysmography (PPG)pulse rate variability (PRV)remote healthcare