Evidence map›Paper›PMID 37177018›Full record

ArticleNanomaterials (Basel, Switzerland)2023

Ultra-Sensitive and Fast Humidity Sensors Based on Direct Laser-Scribed Graphene Oxide/Carbon Nanotubes Composites.

Ammar Al-Hamry, Tianqi Lu, Haoran Chen, Anurag Adiraju, Salem Nasraoui, Amina Brahem, Danica Bajuk-Bogdanović, Saddam Weheabby, Igor A Pašti, Olfa Kanoun

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 30 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Ammar Al-HamryMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0003-0952-3134
Tianqi LuMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0003-0173-7023
Haoran ChenMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.
Anurag AdirajuMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.
Salem NasraouiMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0002-8936-9108
Amina BrahemMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0002-1002-9160
Danica Bajuk-BogdanovićUniversity of Belgrade-Faculty of Physical Chemistry, Studentski trg 12-16, 11158 Belgrade, Serbia.ORCID 0000-0003-2443-376X
Saddam WeheabbyMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0002-7577-900X
Igor A PaštiUniversity of Belgrade-Faculty of Physical Chemistry, Studentski trg 12-16, 11158 Belgrade, Serbia.ORCID 0000-0002-1000-9784
Olfa KanounMeasurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107 Chemnitz, Germany.ORCID 0000-0002-7166-1266
Chemnitz University of Technology · DEUniversity of Belgrade · RS

Funding

Deutsche Forschungsgemeinschaft Photosens" (KA 1663/12) and Dualsens" (KA 1663/13-1)Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) and Chemnitz University of Technology 491193532Serbian Ministry of Science 451-03-47/2023-01/200146
6 · The paper itself

Abstract

In this paper, the relative humidity sensor properties of graphene oxide (GO) and graphene oxide/multiwalled nanotubes (GO/MWNTs) composites have been investigated. Composite sensors were fabricated by direct laser scribing and characterized using UV-vis-NIR, Raman, Fourier transform infrared, and X-ray photoemission spectroscopies, electron scanning microscopy coupled with energy-dispersive X-ray analysis, and impedance spectroscopy (IS). These methods confirm the composite homogeneity and laser reduction of GO/MWNT with dominant GO characteristics, while ISresults analysis reveals the circuit model for rGO-GO-rGO structure and the effect of MWNT on the sensor properties. Although direct laser scribing of GO-based humidity sensor shows an outstanding response (|Δ

Indexed as

carbon nanotubeshumidity sensorimpedance spectroscopylaser direct writingnanocompositereduced graphene oxide

Identifiers

PMID37177018
PMCPMC10180099
OpenAlexW4367051353

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.