Risk of Interprosthetic Femur Fracture Is Associated with Implant Spacing-A Biomechanical Study.

Mischa Mühling, Sabrina Sandriesser, Claudio Glowalla, Sven Herrmann, Peter Augat, Sven Hungerer

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Outcome of surgical fixation of interprosthetic femur fractures: a case series in a district general hospital.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  5. Article
  6. Retrograde Femoral Lengthening Below a Total Hip Arthroplasty.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Mischa MühlingInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.ORCID 0000-0001-5359-0508
Sabrina SandriesserInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.
Claudio GlowallaDepartment of Arthroplasty, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.ORCID 0000-0003-3540-6302
Sven HerrmannInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.
Peter AugatInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.ORCID 0000-0003-4805-2128
Sven HungererInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.ORCID 0000-0002-1615-1423
Paracelsus Medical University · ATBerufsgenossenschaftliche Unfallklinik Murnau · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIpsilateral revision surgeries of total hip or knee arthroplasties due to periprosthetic fractures or implant loosening are becoming more frequent in aging populations. Implants in revision arthroplasty usually require long anchoring stems. Depending on the residual distance between two adjacent knee and hip implants, we assume that the risk of interprosthetic fractures increases with a reduction in the interprosthetic distance. The aim of the current study was to investigate the maximum strain within the femoral shaft between two ipsilateral implants tips.

methodsA simplified physical model consisting of synthetic bone tubes and metallic implant cylinders was constructed and the surface strains were measured using digital image correlation. The strain distribution on the femoral shaft was analyzed in 3-point- and 4-point-bending scenarios. The physical model was transferred to a finite element model to parametrically investigate the effects of the interprosthetic distance and the cortical thickness on maximum strain. Strain patterns for all parametric combinations were compared to the reference strain pattern of the bone without implants.

resultsThe presence of an implant reduced principal strain values but resulted in distinct strain peaks at the locations of the implant tips. A reduced interprosthetic distance and thinner cortices resulted in strain peaks of up to 180% compared to the reference. At low cortical thicknesses, the strain peaks increased exponentially with a decrease in the interprosthetic distance. An increasing cortical thickness reduced the peak strains at the implant tips.

conclusionsA minimum interprosthetic distance of 10 mm seems to be crucial to avoid the accumulation of strain peaks caused by ipsilateral implant tips. Interprosthetic fracture management is more important in patients with reduced bone quality.

Indexed as

interprosthetic fracturekissing implantstotal hip arthroplastytotal knee arthroplasty

Identifiers

PMID37176537
PMCPMC10179557
OpenAlexW4366989391