Evidence map›Paper›PMID 37176385›Full record

ArticleMaterials (Basel, Switzerland)2023

Design and Additive Manufacturing of a Passive Ankle-Foot Orthosis Incorporating Material Characterization for Fiber-Reinforced PETG-CF15.

Patrick Steck, David Scherb, Christian Witzgall, Jörg Miehling, Sandro Wartzack

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. The Determination of Assistance-as-Needed Support by an Ankle-Foot Orthosis for Patients with Foot Drop.International journal of environmental research and public health · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Patrick SteckEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany.ORCID 0000-0001-5213-8800
David ScherbEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany.ORCID 0000-0001-9618-2942
Christian WitzgallEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany.ORCID 0000-0001-7793-4678
Jörg MiehlingEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany.ORCID 0000-0002-8610-1966
Sandro WartzackEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany.ORCID 0000-0002-0244-5033

Funding

Deutsche Forschungsgemeinschaft MI 2608/2-1Deutsche Forschungsgemeinschaft WA 2913/43-1
6 · The paper itself

Abstract

The individualization of patient-specific ankle joint orthoses is becoming increasingly important and can be ideally realized by means of additive manufacturing. However, currently, there are no functional additively manufactured fiber-reinforced products that are used in the field of orthopedic treatment. In this paper, an approach as to how additively manufactured orthopedic products can be designed and produced quickly and flexibly in the future is presented. This is demonstrated using the example of a solid ankle-foot orthosis. For this purpose, test results on PETG-CF15, which were determined in a previous work, were integrated into a material map for an FEA simulation. Therewith, the question can be answered as to whether production parameters that were determined at the test specimen level can also be adapted to real, usable components. Furthermore, gait recordings were used as loading conditions to obtain exact results for the final product. In order to perfectly adapt the design of the splint to the user, a 3D scan of a foot was performed to obtain a perfect design space for topology optimization. This resulted in a patient-specific and stiffness-optimized product. Subsequently, it was demonstrated that the orthosis could be manufactured using fused layer modelling. Finally, a comparison between the conventional design and the consideration of AM-specific properties was made. On this basis, it can be stated that the wearing comfort of the patient-specific design is very good, but the tightening of the splint still needs to be improved.

Indexed as

additive manufacturingankle–foot orthosesankle splintsfiber reinforcementfused layer modellingmaterial characterizationtopology optimizationuser-centered design

Identifiers

PMID37176385
PMCPMC10180110

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked