Evidence map›Paper›PMID 37176341›Full record

ArticleMaterials (Basel, Switzerland)2023

Improving the Surface Integrity of 316L Steel in the Context of Bioimplant Applications.

Krzysztof Szwajka, Joanna Zielińska-Szwajka, Tomasz Trzepieciński

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Krzysztof SzwajkaFaculty of Mechanics and Technology, Department of Integrated Design and Tribology Systems, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland.ORCID 0000-0002-1038-1148
Joanna Zielińska-SzwajkaFaculty of Mechanics and Technology, Department of Component Manufacturing and Production Organization, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland.ORCID 0000-0002-6212-2666
Tomasz TrzepiecińskiDepartment of Manufacturing Processes and Production Engineering, Rzeszow University of Technology, al. Powstańców Warszawy 8, 35-959 Rzeszów, Poland.ORCID 0000-0002-4366-0135

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bioimplants should meet important surface integrity criteria, with the main goal of the manufacturing process to improve wear and corrosion resistance properties. This requires a special approach at the cutting stage. During this research, the impact of the cutting parameters on improving the surface integrity of AISI 316L steel was evaluated. In this context of bioimplant applications, the mean roughness Sa value was obtained in the range of 0.73-4.19 μm. On the basis of the results obtained, a significant effect was observed of both the cutting speed and the feed rate on changes in the microstructure of the near-surface layer. At a cutting speed of 150 m/min, the average grain size was approximately 31 μm. By increasing the cutting speed to 200 m/min, the average grain size increased to approximately 52 μm. The basic austenitic microstructure of AISI 316L steel with typical precipitation of carbides on the grain boundaries was refined at the near-surface layer after the machining process. Changing the cutting speed determined the hardness of the treated and near-surface layers. The maximum value of hardness is reached at a depth of 20 μm and decreases with the depth of measurement. It was also noted that at a depth of up to 240 μm, the maximum hardness of 270-305 HV1 was reached, hence the height of the machining impact zone can be determined, which is approximately 240 μm for almost all machining conditions.

Indexed as

AISI 316Lbioimplanthardnesssurface integritysurface topographyturning

Identifiers

PMID37176341
PMCPMC10180083

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.