ArticleMikrochimica acta2023
Development of cloth-based microfluidic devices for rapid determination of histamine in fish and fishery products.
Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Poly(Neutral Red)-Silver Nanorods-Carbon Nanotubes Composite-Based Ratiometric Electrochemical Sensor for Rapid Detection of Histamine in Crayfish.Foods (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A cloth-based analytical device combined with electrochemiluminescence detection (CAD-ECL) was described for rapid determination of histamine (HA). The CAD device was produced by screen-printing a conductive carbon ink onto a patterned hydrophobic electrochemical microfluidic chamber to fabricate the three-carbon electrode system on a single hydrophilic cloth. The introduction of carbon nanodots linked to chitosan on the working carbon electrode surface enhanced the catalytic performance and overcame the resistance of the cotton fiber material. On this basis, the enhancement of the electrochemiluminescence (ECL) signal of the tris(2,2'-bipyridyl) ruthenium(II) complex, caused by HA, was observed in a phosphate buffer solution at pH 7.6. The proposed CAD-ECL sensor was successfully applied to the quantification of HA in fish and fishery samples with good linearity between ECL intensity and the logarithm of HA concentration in the range 1.0 to 1000.0 µg L
Indexed as
Identifiers
37171641What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.