Evidence map›Paper›PMID 37170691›Full record

ArticleJournal of applied clinical medical physics2023

Effect of extended field-of-view approaches on the accuracy of stopping power ratio estimation for single-energy computed tomography simulators.

Chang-Shiun Lin, Yi-Chun Tsai, Liang-Hsin Chen, Chun-Wei Wang, Chia-Jung Wu, Wan-Yu Chen, Hsiang-Kung Liang, Sung-Hsin Kuo

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Chang-Shiun LinDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.ORCID https://orcid.org/0000-0001-5671-8765
Yi-Chun TsaiDivision of radiation oncology, department of Oncology, National Taiwan University Hospital, Taipei, Taiwan.
Liang-Hsin ChenDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.
Chun-Wei WangDivision of radiation oncology, department of Oncology, National Taiwan University Hospital, Taipei, Taiwan.
Chia-Jung WuDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.
Wan-Yu ChenDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-2483-8292
Hsiang-Kung LiangDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.
Sung-Hsin KuoDepartment of Radiation Oncology, National Taiwan University Cancer Center, Taipei, Taiwan.
National Taiwan University · TWNational Taiwan University Hospital · TW

Funding

National Taiwan University Cancer Center NTUCCS-112-08National Taiwan University Hospital - Taipei Medical University Joint Research Program 112-TMU25
6 · The paper itself

Abstract

backgroundExtended field-of-view (eFOV) methods have been proposed to generate larger demonstration FOVs for computed tomography (CT) simulators with a limited scanning FOV (sFOV) size in order to ensure accurate dose calculation and patient collision avoidance. Although the efficacy of these strategies has been evaluated for photon applications, the effect of stopping power ratio (SPR) estimation on proton therapy has not been studied. This study investigated the effect of an eFOV approach on the accuracy of SPR to water estimation in homogeneous and heterogeneous phantoms. MATERIALS AND

methodsTo simulate patient geometries, tissue-equivalent material (TEM) and customized extension phantoms were used. The TEM phantom supported various rod arrangements through predefined holes. Images were reconstructed to three FOV sizes using a commercial eFOV technique. A single-energy CT stoichiometric method was used to generate Hounsfield unit (HU) to SPR (HU-to-SPR) conversion curves for each FOV. To investigate the effect of rod location in the sFOV and eFOV regions, eight TEM rods were placed at off-center distances in the homogeneous phantom and scanned individually. Similarly, 16 TEM rods were placed in the heterogeneous TEM phantom and scanned simultaneously.

resultsThe conversion curves derived from the sFOV and eFOV data were identical. The average SPR differences of soft-tissue, bone, and lung materials for rods placed at various off-center locations were 3.3%, 4.8%, and 39.6%, respectively. In the heterogeneous phantom, the difference was within 1.0% in the absence of extension. However, in the presence of extension, the difference increased to 2.8% for all rods, except for lung materials, whose difference was 4.8%.

conclusionsWhen an eFOV method is used, the SPR variation in phantoms considerably increases for all TEM rods, especially for lung TEM rods. This phenomenon may substantially increase the uncertainty of HU-to-SPR conversion. Therefore, image reconstruction with a standard FOV size is recommended.

Indexed as

Proton TherapyTomography, X-Ray ComputedBone and BonesHumansImage Processing, Computer-AssistedPhantoms, Imagingconversion curveCTextended field-of-viewHounsfield unitprotonstopping power ratio

Identifiers

PMID37170691
PMCPMC10476990
OpenAlexW4376226308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.