Evidence map›Paper›PMID 37170654›Full record

ArticleJournal of applied clinical medical physics2023

Accuracy and reliability of a commercial treatment planning system in nontarget regions in modern prostate radiotherapy.

Willeke Danckaert, Piet Ost, Carlos De Wagter

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Willeke DanckaertDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
Piet OstDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
Carlos De WagterDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.ORCID https://orcid.org/0000-0002-7426-4282

Funding

Kom op tegen Kanker 13031
6 · The paper itself

Abstract

backgroundThe currently available treatment planning systems (TPSs) are neither designed nor intended for accurate dose calculations in nontarget regions. The aim of this work is to quantify the accuracy and reliability of nontarget doses calculated by a commercially available TPS.

methodsNontarget doses calculated by the collapsed cone (CC) (v5.2) algorithm implemented in the RayStation (v6) TPS were compared to measured values. Different scenarios were investigated, from simple static fields to intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans. Deviations and confidence limits (CLs) were calculated between results of calculations and measurements-applying both local (δ) and global (Δ) normalization-for various points of interest (POIs). Results were based on a single-institution experience for one clinical test case (prostate) and evaluated against internationally accepted criteria.

resultsOverall, the TPS underestimated the nontarget dose by an average of -17.7% ± 25.3% for IMRT. Quantitatively similar results were obtained for VMAT (-17.6% ± 21.2%). POIs receiving < 5% of the prescription dose were significantly underestimated by the TPS (p-value < 0.05 for both IMRT and VMAT). Dose calculation accuracy was also determined by the contribution of secondary radiation, with measured doses for out-of-field POIs being significantly different from calculated values (p-value < 0.01 for both IMRT and VMAT). Although the CL

conclusionsBased on the currently available benchmarks our TPS is considered acceptable for clinical use, although the dose in some POIs was poorly predicted by the CC algorithm. Some areas were pointed out where TPSs and linear accelerator control systems can be improved.

Indexed as

ProstateRadiotherapy, Intensity-ModulatedHumansMaleRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReproducibility of Resultsmicrodiamond detectornontarget dose accuracytreatment planning system

Identifiers

PMID37170654
PMCPMC10402685

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.