Evidence map›Paper›PMID 37168315›Full record

ArticleAdvances in radiation oncology

The use of a wearable cardioverter defibrillator during postmastectomy radiotherapy as an alternative for relocation of the pulse generator.

Phil W Koken, Desirée H J G van den Bongard, Kirsten M Kooiman

Abstract read
In one paragraph

Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Phil W KokenDepartment of Radiation Oncology, Amsterdam UMC, Amsterdam, The Netherlands.
Desirée H J G van den BongardDepartment of Radiation Oncology, Amsterdam UMC, Amsterdam, The Netherlands.
Kirsten M KooimanDepartment of Cardiology, Clinical Electrophysiology, Amsterdam UMC, Amsterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: We describe a case in which a breast cancer patient with an implantable cardioverter-defibrillator (ICD) was treated with postmastectomy followed by axillary radiation therapy. The ICD was partly within the target volume and according to the treatment planning system would receive a maximum dose of about 36 Gy. Methods and Materials: Postoperatively, the patient had a wound infection needing surgical intervention and 3 months of antibiotics. Therefore, it was decided not to relocate the ICD but instead to switch off the shock function of the ICD for the entire radiation therapy course. Results: The ICD was successfully substituted with a wearable cardioverter defibrillator (WCD), which the patient wore during the 3-week radiation therapy period until 2 weeks after the end of treatment. The ICD function was monitored from the start of the treatment until 6 months after treatment. Conclusions: In situations in which an ICD needs to be switched off semipermanently, a WCD can be used as alternative. The patient in this report tolerated the WCD well. Despite the high dose received by the ICD, the device and its battery continued to function normally.