Evidence map›Paper›PMID 37167217›Full record

ArticlePloS one2023

Multi-planar 2.5D U-Net for image quality enhancement of dental cone-beam CT.

Kanghyun Ryu, Chena Lee, Yoseob Han, Subeen Pang, Young Hyun Kim, Chanyeol Choi, Ikbeom Jang, Sang-Sun Han

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Kanghyun RyuArtificial Intelligence and Robotics Institute, Korea Institute of Science and Technology, Seoul, South Korea.
Chena LeeDepartment of Oral and Maxillofacial Radiology, Yonsei University College of Dentistry, Seoul, South Korea.ORCID 0000-0002-8943-4192
Yoseob HanCollege of Information Technology, Department of Electronic Engineering, IT Convergence Major, Soongsil University, Seoul, Korea.
Subeen PangDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America.
Young Hyun KimDepartment of R&D Performance Evaluation, Korea Health Industry Development Institute (KHIDI), Cheongju, South Korea.
Chanyeol ChoiDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America.
Ikbeom JangDivision of Computer Engineering, Hankuk University of Foreign Studies, Yongin, South Korea.
Sang-Sun HanDepartment of Oral and Maxillofacial Radiology, Yonsei University College of Dentistry, Seoul, South Korea.ORCID 0000-0003-1775-7862
Harvard University · USMassachusetts Institute of Technology · USYonsei University · KRKorea Health Industry Development Institute · KRKorean Association Of Science and Technology Studies · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cone-beam computed tomography (CBCT) can provide 3D images of a targeted area with the advantage of lower dosage than multidetector computed tomography (MDCT; also simply referred to as CT). However, in CBCT, due to the cone-shaped geometry of the X-ray source and the absence of post-patient collimation, the presence of more scattering rays deteriorates the image quality compared with MDCT. CBCT is commonly used in dental clinics, and image artifacts negatively affect the radiology workflow and diagnosis. Studies have attempted to eliminate image artifacts and improve image quality; however, a vast majority of that work sacrificed structural details of the image. The current study presents a novel approach to reduce image artifacts while preserving details and sharpness in the original CBCT image for precise diagnostic purposes. We used MDCT images as reference high-quality images. Pairs of CBCT and MDCT scans were collected retrospectively at a university hospital, followed by co-registration between the CBCT and MDCT images. A contextual loss-optimized multi-planar 2.5D U-Net was proposed. Images corrected using this model were evaluated quantitatively and qualitatively by dental clinicians. The quantitative metrics showed superior quality in output images compared to the original CBCT. In the qualitative evaluation, the generated images presented significantly higher scores for artifacts, noise, resolution, and overall image quality. This proposed novel approach for noise and artifact reduction with sharpness preservation in CBCT suggests the potential of this method for diagnostic imaging.

Indexed as

Image EnhancementImaging, Three-DimensionalArtifactsCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedPhantoms, ImagingRetrospective Studies

Identifiers

PMID37167217
PMCPMC10174510
OpenAlexW4376225151

What OpenQuestion holds

Textmetadata
LicenceCC0
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.