Trial reportJAMA ophthalmology2023
Swab Pressing vs Stromal Hydration to Prevent Incision Leakage and Transient Collapse of Anterior Chamber in Phacoemulsification: A Randomized Clinical Trial.
Trial report in JAMA ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of Wound Integrity for Clear Corneal Cataract Incisions: Pressure Versus Stromal Hydration
The Impact of Surgical Procedures on Postoperative Outcomes in Cataract Phacoemulsification and Analysis of Related Factors
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- An applied study of phacoemulsification cataract surgery with the mortise and tenon limbal incision.Scientific reports · 2025Article
- Impact of Corneal Arcus on the Sealing of Clear Corneal Incisions in Cataract Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
Corrections and comments
- Commented on by
Authors and funding
9 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: During phacoemulsification, incision leakage and the subsequent anterior chamber collapse often occur after the withdrawal of the handpiece, which cannot be prevented by current sealing techniques. A new technique called swab pressing is proposed here to apply pressure with a cotton swab to seal the incision immediately, but efficacy remains unknown. Objective: To determine if swab pressing is noninferior to stromal hydration, the current practice, in sealing incisions in phacoemulsification for age-related cataract. Design, Setting, and Participants: This noninferiority randomized controlled clinical trial was conducted between February 2022 and September 2022 at the Zhongshan Ophthalmic Center, Guangzhou, China. Patients aged 60 to 90 years with age-related cataract were enrolled. Interventions: Participants were randomly assigned (1:1) to receive swab pressing or stromal hydration. All surgeries were performed by a single experienced surgeon who was unmasked to the assignment. Main Outcomes and Measures: The proportion of closed clear corneal incisions evaluated using intraoperative optical coherence tomography. Results: A total of 126 eyes of 126 participants were randomized into the swab pressing group (63 [50%]) and stromal hydration group (63 [50%]). The mean (SD) age of participants was 69.2 (6.14) years and 70.1 (7.67) years in the pressing and stromal hydration groups, respectively. A total of 39 participants (61.9%) in the pressing group and 35 (55.6%) in the modified group were female. The proportion of closed incisions was 96.8% (61 of 63) in the swab pressing group and 93.7% (59 of 63) in the stromal hydration group. Noninferiority was met, as the lower 95% CI of -5.83 percentage points was greater than the prescribed noninferiority margin of -6.60 percentage points (difference, 3.17 percentage points; 95% CI, -5.83 to 12.18 percentage points). The rate of anterior chamber collapse (pressing: 0 of 63 vs stromal hydration: 35 of 63 [55.6%]; P < .001) was lower in the swab pressing group. There were no differences between the 2 groups in the proportion of closed incisions and central anterior chamber depth at postoperative hour 1 and day 1. Conclusions and Relevance: In this study, swab pressing was noninferior to stromal hydration in sealing clear corneal incisions in phacoemulsification for age-related cataract. While this trial involved only 1 surgeon who was not masked to the interventions, the results suggest that swab pressing is feasible and further investigations would be warranted to determine if it prevents the intraoperative transient collapse of anterior chamber or affects visual acuity outcomes. Trial Registration: ClinicalTrials.gov Identifier: NCT05242653.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.