Observational studyJournal of clinical monitoring and computing2023
Evaluation of the accuracy of oscillometric non-invasive blood pressure measurement at the ankle in children during general anesthesia.
Observational study in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Accuracy of ankle versus arm oscillometric non-invasive blood pressure in detecting hypotension during shoulder surgery in the beach-chair position: A prospective observational study.Indian journal of anaesthesia · 2026Article
- Accuracy of oscillometric noninvasive blood pressure at the ankle in the lateral position during general anesthesia.BMC anesthesiology · 2024Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to evaluate the accuracy of oscillometric blood pressure measurement at the ankle in children using invasive blood pressure as reference standard. This prospective observational study included children undergoing noncardiac surgery. Paired radial invasive and ankle non-invasive blood pressure measurements were obtained. Delta blood pressure was calculated as the difference between two consecutive readings. The primary outcome was the mean bias and agreement between the two methods using the Bland-Altman analysis. The ISO standard was fulfilled if the mean bias between the two methods was ≤ 5 ± 8 mmHg. Other outcomes included the trending ability of ankle blood pressure using the four-quadrant plot and the accuracy of ankle measurement to detect hypotension using area under receiver operating characteristic curve (AUC) analysis. We analyzed 683 paired readings from 86 children. The mean bias between the two methods for systolic, diastolic, and mean blood pressure (SBP, DBP, MAP) was - 7.2 ± 10.7, 4.5 ± 12.8, and - 1.8 ± 8.2 mmHg, respectively. The concordance rate of ankle blood pressure was 72%, 71%, and 77% for delta SBP, DBP and MAP, respectively. The AUC (95% confidence interval) for ankle MAP ability to detect hypotension was 0.91 (0.89-0.93) with negative predictive value of 100% at cut-off value ≤ 70 mmHg, We concluded that in pediatric population undergoing noncardiac surgery, ankle blood pressure was not interchangeable with the corresponding invasive readings with the ankle MAP having the least bias compared to SBP and DBP. An ankle MAP > 70 mmHg can exclude hypotension with negative predictive value of 100%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.