Evidence map›Paper›PMID 37166553›Full record

ArticleNeurosurgical review2023

Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods.

Lu-Ping Zhou, Ren-Jie Zhang, Wen-Kui Zhang, Liang Kang, Kai-Xuan Li, Hua-Qing Zhang, Chong-Yu Jia, Yin-Shun Zhang, Cai-Liang Shen

Abstract read
PubMed Publisher
In one paragraph

Article in Neurosurgical review, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
7.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  8. Robotic assistance for upper cervical instrumentation: report on accuracy and safety.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Lu-Ping Zhou *Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Ren-Jie Zhang *Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Wen-Kui Zhang *Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Liang KangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Kai-Xuan LiDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Hua-Qing ZhangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Chong-Yu JiaDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
Yin-Shun ZhangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China. zhangyinshun@126.com.
Cai-Liang ShenDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China. shencailiang@ahmu.edu.cn.ORCID https://orcid.org/0000-0002-9835-6384
Anhui Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The novel robot-assisted (RA) technique has been utilized increasingly to improve the accuracy of cervical pedicle screw placement. Although the clinical application of the RA technique has been investigated in several case series and comparative studies, the superiority and safety of RA over conventional freehand (FH) methods remain controversial. Meanwhile, the intra-pedicular accuracy of the two methods has not been compared for patients with cervical traumatic conditions. This study aimed to compare the rate and risk factors of intra-pedicular accuracy of RA versus the conventional FH approach for posterior pedicle screw placement in cervical traumatic diseases. A total of 52 patients with cervical traumatic diseases who received cervical screw placement using RA (26 patients) and FH (26 patients) techniques were retrospectively included. The primary outcome was the intra-pedicular accuracy of cervical pedicle screw placement according to the Gertzbin-Robbins scale. Secondary outcome parameters included surgical time, intraoperative blood loss, postoperative drainage, postoperative hospital stay, and complications. Moreover, the risk factors that possibly affected intra-pedicular accuracy were assessed using univariate analyses. Out of 52 screws inserted using the RA method, 43 screws (82.7%) were classified as grade A, with the remaining 7 (13.5%) and 2 (3.8%) screws classified as grades B and C. In the FH cohort, 60.8% of the 79 screws were graded A, with the remaining screws graded B (21, 26.6%), C (8, 10.1%), and D (2, 2.5%). The RA technique showed a significantly higher rate of optimal intra-pedicular accuracy than the FH method (P = 0.008), but there was no significant difference between the two groups in terms of clinically acceptable accuracy (P = 0.161). Besides, the RA technique showed remarkably longer surgery time, less postoperative drainage, shorter postoperative hospital stay, and equivalent intraoperative blood loss and complications than the FH technique. Furthermore, the univariate analyses showed that severe obliquity of the lateral atlantoaxial joint in the coronal plane (P = 0.003) and shorter width of the lateral mass at the inferior margin of the posterior arch (P = 0.014) were risk factors related to the inaccuracy of C1 screw placement. The diagnosis of HRVA (P < 0.001), severe obliquity of the lateral atlantoaxial joint in the coronal plane (P < 0.001), short pedicle width (P < 0.001), and short pedicle height (P < 0.001) were risk factors related to the inaccuracy of C2 screw placement. RA cervical pedicle screw placement was associated with a higher rate of optimal intra-pedicular accuracy to the FH technique for patients with cervical traumatic conditions. The severe obliquity of the lateral atlantoaxial joint in the coronal plane independently contributed to high rates of the inaccuracy of C1 and C2 screw placements. RA pedicle screw placement is safe and useful for cervical traumatic surgery.

Indexed as

Atlanto-Axial JointPedicle ScrewsRoboticsSpinal FusionCervical VertebraeHumansRetrospective StudiesCervical traumatic diseasesFreehandPedicle screw accuracyPosterior cervicalRisk factorRobot-assisted screw placement

Identifiers

PMID37166553
OpenAlexW4376131076

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.