ArticleInsights into imaging2023
Comparison between percutaneous transthoracic co-axial needle CT-guided biopsy and transbronchial lung biopsy for the diagnosis of persistent pulmonary consolidation.
Article in Insights into imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- Diagnostic accuracy and safety of 1.1-mm cryoprobe biopsy for peripheral pulmonary lesions with or without oversheath.Translational lung cancer research · 2026Article
- Factors Influencing Diagnostic Yield and Complication Risk in CT-Guided Transthoracic Lung Biopsy of Pulmonary Lesions: A Retrospective Analysis.Diagnostics (Basel, Switzerland) · 2026Article
- Machine learning predicts severe adverse events and salvage success of CT-guided lung biopsy after nondiagnostic transbronchial lung biopsy.European radiology · 2026Article
- CT-Guided Percutaneous Lung Biopsy: Important Steps with "Tips and Tricks" for Optimal Yield.The Indian journal of radiology & imaging · 2025Review
- Efficacy and safety in synchronous core-needle biopsy and cryoablation for highly suspicious malignant pulmonary nodule.Cancer imaging : the official publication of the International Cancer Imaging Society · 2025Article
- Article
- Accurate puncture of targets in the lower lung lobes with respiratory motion using a teleoperated robotic system and low-dose computed tomography fluoroscopy: an experimental animal study.Quantitative imaging in medicine and surgery · 2025Article
- Comparison Between Endobronchial-Guided Transbronchial Biopsy and Computed Tomography-Guided Transthoracic Lung Biopsy for the Diagnosis of Central Pulmonary Lesions.The clinical respiratory journal · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundDiagnosing persistent pulmonary consolidation still faces challenges. The purpose of this study is to compare the diagnostic yield and the complication rate between percutaneous transthoracic CT-guided coaxial needle biopsy (PTCNB) and transbronchial lung biopsy (TBLB) of persistent pulmonary consolidation. MATERIALS: From January 1, 2016, to December 31, 2020, we have retrospectively enrolled a total of 155 consecutive patients (95 males, 60 females) with persistent pulmonary consolidation who underwent both TBLB and PTCNB. According to the standard reference, the diagnostic yield, accuracy, sensitivity and specificity of PTCNB and TBLB were assessed and compared.
resultsAccording to the standard reference, the final biopsy diagnoses of 11 cases were confirmed true malignant based on the surgical resections, the remaining were confirmed by clinical and imaging follow-up for at least 12 months. The overall diagnostic accuracy, sensitivity and specificity of PTCNB for malignant diagnosis were 91.61%, 72.34% and 100%, whereas of TBLB were 87.74%, 59.57% and 100%. The diagnostic yield of PTCNB and TBLB were 50.32% and 25.16%, respectively. For the TBLB-based negative cases, PTCNB provided a definite diagnostic yield of 37.93%. There were 45 (29.03%), 22 (14.19%) and 13 (8.39%) patients who experienced pneumothorax, intrapulmonary hemorrhage and hemoptysis, respectively, in PTCNB, while there were only 5 (3.22%) cases of mild intraprocedural bleeding occurring in TBLB.
conclusionsCT-guided co-axial needle biopsy is an effective and safe modality, associated with higher diagnostic yield and better diagnostic accuracy compared to transbronchial lung biopsy for malignancy presenting as persistent consolidation, especially as the complementary method for TBLB-based negative lung lesions. KEY POINTS: Both PTCNB and TBLB showed high diagnostic accuracy for malignancy. PTCNB had a higher diagnostic yield than TBLB for persistent pulmonary consolidation. PTCNB could provide a complementary diagnosis for TBLB-based negative lung consolidation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.