Evaluation of commercial devices for patient specific QA of stereotactic radiotherapy plans.

Shands James, Ahmad Al-Basheer, Eric Elder, Chulhaeng Huh, Christopher Ackerman, John Barrett, Russell Hamilton, Farshad Mostafaei

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT.Journal of applied clinical medical physics · 2025
    Guideline
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shands JamesDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.
Ahmad Al-BasheerDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.
Eric ElderNuclear/Radiological Engineering/Medical Physics Department, Georgia Institute of Technology, Atlanta, Georgia, USA.
Chulhaeng HuhDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.
Christopher AckermanDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.
John BarrettDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.
Russell HamiltonDepartment of Radiation Oncology, University of Arizona, Tucson, Arizona, USA.
Farshad MostafaeiDepartment of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stereotactic radiotherapy (SRT) methods have become common for the treatment of small tumors in various parts of the body. Small field dosimetry has a unique set of challenges when it comes to the pre-treatment validation of a radiotherapy plan that involves film dosimetry or high-resolution detectors. Comparison of commercial quality assurance (QA) devices to the film dosimetry method for pre-treatment evaluation of stereotactic radiosurgery (SRS), fractionated SRT, and stereotactic body radiation therapy treatment plans have been evaluated in this study. Forty stereotactic QA plans were measured using EBT-XD film, IBA Matrixx Resolution, SNC ArcCHECK, Varian aS1200 EPID, SNC SRS MapCHECK, and IBA myQA SRS. The results of the commercial devices are compared to the EBT-XD film dosimetry results for each gamma criteria. Treatment plan characteristics such as modulation factor and target volume were investigated for correlation with the passing rates. It was found that all detectors have greater than 95% passing rates at 3%/3 mm. Passing rates decrease rapidly for ArcCHECK and the Matrixx as criteria became more strict. In contrast, EBT-XD film, SNC SRS MapCHECK, and IBA myQA SRS passing rates do not decline as rapidly when compared to Matrix Resolution, ArcCHECK, and the EPID. EBT-XD film, SNC SRS MapCHECK, and IBA myQA SRS maintain greater than 90% passing rate at 2%/1 mm and greater than 80% at 1%/1 mm. Additionally, the ability of these devices to detect changes in dose distribution due to MLC positioning errors was investigated. Ten VMAT SBRT/SRS treatment plans were created with 6 MV FFF or 10 MV FFF beam energies using Eclipse 15.6. A MATLAB script was used to create two MLC positioning error scenarios from the original treatment plan. It was found that errors in MLC positioning were most reliably detected at 2%/1 mm for high-resolution detectors and that lower-resolution detectors did not consistently detect MLC positioning errors.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedHumansQuality Assurance, Health CareRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-Assisteddiodeselectronic portal imaging devicequality assuranceradiochromic filmstereotactic body radiation therapystereotactic radiosurgery

Identifiers

PMID37158727
PMCPMC10402672

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.