ArticleScientific reports2023
Hemodynamic and recirculation performance of dual lumen cannulas for venovenous extracorporeal membrane oxygenation.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 18 citations in OpenAlex.
- Digital performance testing reveals how redesigned return cannulas can enhance VV-ECMO performance.Intensive care medicine experimental · 2026Article
- A Novel Method for Predicting Recirculation by Sweep-Gas Control in Extracorporeal Membrane Oxygenation.Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia · 2026Article
- Influence of side-hole configuration on recirculation in dual-lumen cannulas for veno-venous extracorporeal membrane oxygenation: a parametric computational fluid dynamics study.Frontiers in bioengineering and biotechnology · 2026Article
- The Impact of Venovenous Extracorporeal Membrane Oxygenation Cannulation Configuration on Hemodynamic Characteristics and Risks of Hemolysis.Annals of biomedical engineering · 2025Article
- Hemodynamics in femoro-femoral venovenous extracorporeal membrane oxygenation using large eddy simulations.Scientific reports · 2025Article
- Extracorporeal life support for adult patients with ARDS.Intensive care medicine · 2025Review
- Impact of Cannulation Strategy and Extracorporeal Blood Flow on Recirculation During Veno-Venous Extracorporeal Membrane Oxygenation.Artificial organs · 2025Observational
- Managing Refractory Hypoxemia in Acute Respiratory Distress Syndrome Obese Patients with Veno-Venous Extra-Corporeal Membrane Oxygenation: A Narrative Review.Journal of clinical medicine · 2025Review
- Mechanisms of limitation of oxygen delivery during veno-venous extracorporal membrane oxygenation.Journal of thoracic disease · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Venovenous extracorporeal membrane oxygenation (ECMO) can be performed with two single lumen cannulas (SLCs) or one dual-lumen cannula (DLC) where low recirculation fraction ([Formula: see text]) is a key performance criterion. DLCs are widely believed to have lower [Formula: see text], though these have not been directly compared. Similarly, correct positioning is considered critical although its impact is unclear. We aimed to compare two common bi-caval DLC designs and quantify [Formula: see text] in several positions. Two different commercially available DLCs were sectioned, measured, reconstructed, scaled to 27Fr and simulated in our previously published patient-averaged computational model of the right atrium (RA) and venae cavae at 2-6 L/min. One DLC was then used to simulate ± 30° and ± 60° rotation and ± 4 cm insertion depth. Both designs had low [Formula: see text] (< 7%) and similar SVC/IVC drainage fractions and pressure drops. Both cannula reinfusion ports created a high-velocity jet and high shear stresses in the cannula (> 413 Pa) and RA (> 52 Pa) even at low flow rates. Caval pressures were abnormally high (16.2-23.9 mmHg) at low flow rates. Rotation did not significantly impact [Formula: see text]. Short insertion depth increased [Formula: see text] (> 31%) for all flow rates whilst long insertion only increased [Formula: see text] at 6 L/min (24%). Our results show that DLCs have lower [Formula: see text] compared to SLCs at moderate-high flow rates (> 4 L/min), but high shear stresses. Obstruction from DLCs increases caval pressures at low flow rates, a potential reason for increased intracranial hemorrhages. Cannula rotation does not impact [Formula: see text] though correct insertion depth is critical.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.