Evidence map›Paper›PMID 37154911›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Valgus alignment of the femoral component is associated with higher revision rates 10 years after TKA.

T Luyckx, R Moreels, H Geernaert, L Scheys, H Vandenneucker

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. [Application of transverse tibial axis reference method in rotational positioning of femoral prosthesis in total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  4. Article
  5. Observational
  6. Is technological-assisted leg axis alignment reliable in total knee arthroplasty with varus-valgus deformities?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

T LuyckxDepartment of Orthopaedic Surgery and Traumatology, AZ Delta Roeselare, Roeselare, Belgium.
R MoreelsDepartment of Orthopaedic Surgery and Traumatology, AZ Delta Roeselare, Roeselare, Belgium. robin.moreels@outlook.com.ORCID http://orcid.org/0000-0002-4263-922X
H GeernaertDepartment of Orthopaedic Surgery, University Hospitals Leuven, Leuven, Belgium.
L ScheysDepartment of Development and Regeneration, Institute for Orthopaedic Research and Training (IORT), University Hospitals Leuven, Leuven, Belgium.
H VandenneuckerDepartment of Orthopaedic Surgery, University Hospitals Leuven, Leuven, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAppropriate positioning and alignment of tibial and femoral component in primary total knee arthroplasty (TKA) are factors of major importance directly related to patient satisfaction and implant survival. Most literature works elaborate on overall post-operative alignment and its correlation to implant survival. However, less is known about the impact of individual component alignment. The purpose of this study was to investigate the effect of undercorrection of overall alignment as well as the effect of individual tibial and femoral component alignment on the post-operative failure rate after total knee arthroplasty.

methodsClinical and radiographic data of primary TKA cases from 2002 to 2004, with a minimum of 10-year follow-up, were retrospectively reviewed. The pre- and post-operative hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured on weight-bearing, full-length antero-posterior lower limb radiographs. Statistical analysis was performed to establish the correlation between both overall and implant alignment and revision rate.

resultsIn total, 379 primary TKA cases were evaluated. The mean time of follow-up was 12.9 years (range 10.3-15.9 years, SD = 1.8). Nine out of 379 cases were revised due to aseptic loosening; the mean time to revision was 5.5 years (range 1.0-15.5 years, SD = 4.6). Varus undercorrection of overall alignment was not associated with a higher rate of revision (p = 0.316). Post-operative valgus femoral alignment (mLDFA < 87°) contributed to a significant decreased prosthesis survival in contrast to neutral femoral alignment (revision rate valgus group: 10.7% and neutral group: 1.7%; p = 0.003). Post-operative tibial mechanical alignment was not identified as a significant predictor for implant survival (revision rate varus group: 2.9% and neutral group: 2.4%; p = 0.855).

conclusionsPrimary TKA showed significantly higher revision rates when the femoral component was placed in > 3° of valgus (mLDFA < 87°). In contrast, postoperative overall residual varus alignment (HKA) and varus alignment of the tibial component were not related to higher revision rates at a minimum 10-year follow-up after TKA. These findings should be considered when choosing component position in individualised TKA. LEVEL OF EVIDENCE: III.

Indexed as

Arthroplasty, Replacement, KneeOsteoarthritis, KneeHumansKneeKnee JointRetrospective StudiesComponent alignmentFollow-upImplant survivalRevision rateTotal knee arthroplastyVarus undercorrection

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.