ArticleOrthopaedic surgery2023
The Relation between the Dynamization of Hexapod Circular External Fixator and Tibial Mechanical Properties.
Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Revisiting bone healing strategies: the potential of reverse dynamization in veterinary orthopedics.Frontiers in veterinary science · 2026Review
- Fixators dynamization for delayed union and non-union of femur and tibial fractures: a review of techniques, timing and influence factors.Journal of orthopaedic surgery and research · 2023Review
- Finite Element Analysis of Von Mises Stress in External Fixators for Open Tibial Fractures: A Comparative Study of ASTM F1541-02 and Tibia-Based Models in Indonesian Patients.Healthcare technology lettersArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
objectiveDynamization of the external fixator, defined as gradually decreasing construct-stability of the fixator, is widely accepted as a method for treatment during the late phase of the bone healing process. However, the dynamization is mostly based on the subjective experience of orthopaedists at present, without unified standards and a clear theoretical basis. The objective of the study is to investigate the influence of the dynamization operations on the tibial mechanical properties with a hexapod circular external fixator and standardize the dynamization process.
methodsA 3D-printed tibial defects model with Young's modulus of 10.5 GPa and Poisson's ratio of 0.32 simulated the clinically fractured bone. A 10 × ∅ 45 mm silicone sample with Young's modulus of 2.7 MPa and Poisson's ratio of 0.32 simulated the callus in the fracture site. Furthermore, a hexapod circular external fixator whose struts were coded from #1 to #6 was fixed on the model with six half-pins (5 mm diameter). Corresponding to the action of removing and loosening the struts, 17 dynamization operations are designed. For each construct after different dynamization operations, the mechanical environment changes in the fracture site were recorded by a triaxle forces sensor under gradually increasing external load from 0 to 500 N.
resultsThe results show that the bone axial load-sharing ratio of each construct in the removal group was generally higher than that in the loosening group. The ratio increased from 92.51 ± 0.74% to 102.68 ± 0.27% with the number of operated struts rising from 2 to 6. Besides, the constructions with the same number of operated struts but with different strut codes such as constructions 3-5, had similar bone axial load-sharing ratios. In addition, the proposed dynamization method of the hexapod circular external fixator can gradually increase the bone axial load-sharing ratio from 90.73 ± 0.19% to 102.68 ± 0.27% and maintain the bone radial load-sharing ratio below 8%.
conclusionThe laboratory study verified the effects of the type of operations and the number of operated struts on the bone axial load-sharing ratio, as well as the slight influence of the choice of the strut code. Besides, a dynamization method of the hexapod circular external fixator was proposed to increase the bone axial load-sharing ratio gradually.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.