Evidence map›Paper›PMID 37153380›Full record

ArticleHeliyon2023

Process analytical technology as in-process control tool in semi-continuous manufacturing of PLGA/PEG-PLGA microspheres.

Arfidin Anwar, Pengfei Sun, Xiaoxu Rong, Abdulaziz Arkin, Aliya Elham, Zilala Yalkun, Xun Li, Mubarak Iminjan

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Nanotechnology boosts the efficiency of tumor diagnosis and therapy.Frontiers in bioengineering and biotechnology · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Arfidin AnwarDepartment of Pharmaceutics and Physical Chemistry, College of Pharmacy, Xinjiang Medical University, Urumqi, 830017, China.
Pengfei SunUniversity of Wisconsin-Madison, Department of Educational Psychology, Madison, USA.
Xiaoxu RongUniversity of Wisconsin-Madison, Department of Educational Psychology, Madison, USA.
Abdulaziz ArkinDepartment of Pharmaceutics and Physical Chemistry, College of Pharmacy, Xinjiang Medical University, Urumqi, 830017, China.
Aliya ElhamDepartment of Pharmaceutics and Physical Chemistry, College of Pharmacy, Xinjiang Medical University, Urumqi, 830017, China.
Zilala YalkunCollege of Pharmacy, Dalian Medical University, Dalian, 116000, China.
Xun LiChinese Academy of Science, Department of Chemical Engineering, Beijing, 100190, China.
Mubarak IminjanDepartment of Pharmaceutics and Physical Chemistry, College of Pharmacy, Xinjiang Medical University, Urumqi, 830017, China.
Xinjiang Medical University · CNUniversity of Wisconsin–Madison · USDalian Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nowadays, among 3rd generation drug delivery systems, biodegradable polymeric based long-acting injectable depot has achieved tremendous success in clinical application. So far, there have been two dozen of commercial products of Poly (lactic-co-glycolic acid) microspheres available in the market. Recently, continuous manufacturing concept has been successfully applied on oral solid formulation from buzzword to reality. However, the polymeric injectable microspheres are still stayed at batch manufacturing phase due to the lack of understanding of knowledge matrix. In this study, micro-mixer as a plug-and-play emulsification modules, Raman spectroscopy and focused beam reflectance measurement as real-time monitoring modules are integrated into a novel semi-continuous manufacturing streamline to provides more efficient upscaling flexibility in microspheres production. In this end to end semi-continuous manufacturing process, amphiphilic block polymer monomethoxy-poly (ethylene glycol) modified PLGA (mPEG-PLGA) was used for encapsulating Gallic acid. Additionally, with guarantee of good robustness, the correlation relationship between critical process parameters, critical material attributes and critical quality attributes were investigated. The time-space evolution process and mechanism for formation of PEG-PLGA microsphere with particular morphology were elaborated. Altogether, this study firstly established semi-continuous manufacturing streamline for PLGA/PEG-PLGA microspheres, which would not only lower the cost of production, narrow process variability and smaller equipment/environmental footprint but also applied in-process control (IPC) and QbD principle on complicated production process of microspheres. Therefore, this study build confidence in the industrial development of PLGA/PEG-PLGA microspheres and establish best practice standards, which might be a quantum leap for developing PLGA microspheres in the future.

Indexed as

And real-time monitorContinuous manufacturingIn-process controlmPEG-PLGA/PLGA, process analytical technology

Identifiers

PMID37153380
PMCPMC10160502
OpenAlexW4366753687

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.