Evidence map›Paper›PMID 37152558›Full record

ArticleRSC advances2023

A highly explicit electrochemical biosensor for catechol detection in real samples based on copper-polypyrrole.

Qasar Saleem, Sammia Shahid, Abdur Rahim, Majed A Bajaber, Sana Mansoor, Mohsin Javed, Shahid Iqbal, Ali Bahadur, Samar O Aljazzar, Rami Adel Pashameah and 3 more

Open access · goldAbstract read
In one paragraph

Article in RSC advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 17 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 8 institutions in 3 countries.

Qasar SaleemDepartment of Chemistry, School of Science, University of Management and Technology Lahore 54770 Pakistan.
Sammia ShahidDepartment of Chemistry, School of Science, University of Management and Technology Lahore 54770 Pakistan.
Abdur RahimDepartment of Chemistry, COMSATS University Islamabad Pakistan abdur.rahim@comsats.edu.pk.
Majed A BajaberChemistry Department, Faculty of Science, King Khalid University P. O. Box 9004 Abha 61413 Saudi Arabia.
Sana MansoorDepartment of Chemistry, School of Science, University of Management and Technology Lahore 54770 Pakistan.
Mohsin JavedDepartment of Chemistry, School of Science, University of Management and Technology Lahore 54770 Pakistan.
Shahid IqbalDepartment of Chemistry, School of Natural Sciences (SNS), National University of Science and Technology (NUST) H-12 Islamabad 46000 Pakistan shahidgcs10@yahoo.com.ORCID https://orcid.org/0000-0001-8495-2890
Ali BahadurDepartment of Chemistry, College of Science and Technology, Wenzhou-Kean University Wenzhou 325060 China abahadur@wku.edu.cn.
Samar O AljazzarDepartment of Chemistry, College of Science, Princess Nourah bint Abdulrahman University P. O. Box 84428 Riyadh 11671 Saudi Arabia.
Rami Adel PashameahDepartment of Chemistry, Faculty of Applied Science, Umm Al-Qura University Makkah 24230 Saudi Arabia.
Samah A AlSubhiLaboratory Medicine Department, Faculty of Applied Medical Science, Umm Al-Qura University Makkah Saudi Arabia.
Eman AlzahraniDepartment of Chemistry, College of Science, Taif University P. O. Box 11099 Taif 21944 Saudi Arabia.
Abd-ElAziem FaroukDepartment of Chemistry, College of Science, Taif University P. O. Box 11099 Taif 21944 Saudi Arabia.
University of Management and Technology · PKTaif University · SAUmm al-Qura University · SACOMSATS University Islamabad · PKKing Khalid University · SANational University of Sciences and Technology · PKPrincess Nourah bint Abdulrahman University · SAWenzhou-Kean University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Catechol is a pollutant that can lead to serious health issues. Identification in aquatic environments is difficult. A highly specific, selective, and sensitive electrochemical biosensor based on a copper-polypyrrole composite and a glassy carbon electrode has been created for catechol detection. The novelty of this newly developed biosensor was tested using electrochemical techniques. The charge and mass transfer functions and partially reversible oxidation kinetics of catechol on the redesigned electrode surface were examined using electrochemical impedance spectroscopy and cyclic voltammetry scan rates. Using cyclic voltammetry, chronoamperometry, and differential pulse voltammetry, the characteristics of sensitivity (8.5699 μA cm

Identifiers

PMID37152558
PMCPMC10155604
OpenAlexW4368239174

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.