Evidence map›Paper›PMID 37152083›Full record

ReviewPorto biomedical journal

Diagnosis of pathological conditions through electronic nose analysis of urine samples: a systematic review and meta-analysis.

Helga A S Afonso, Mariana V Farraia, Mónica A Vieira, João Cavaleiro Rufo

Open access · diamondAbstract readReview
In one paragraph

Review in Porto biomedical journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Observational
  2. Review
  3. Electronic nose versus VITEK 2 system for the rapid diagnosis of bloodstream infections.Brazilian journal of microbiology : [publication of the Brazilian Society for Microbiology] · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Helga A S AfonsoEscola Superior de Saúde, Instituto Politécnico do Porto, Porto, Portugal.
Mariana V FarraiaEPIUnit-Institute of Public Health, University of Porto, Porto, Portugal.
Mónica A VieiraEscola Superior de Saúde, Instituto Politécnico do Porto, Porto, Portugal.
João Cavaleiro RufoEPIUnit-Institute of Public Health, University of Porto, Porto, Portugal.ORCID https://orcid.org/0000-0003-1175-242X
Apple (Israel) · ILUniversidade do Porto · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Currently available urinalysis methods are often applied for screening and monitoring of several pathologies. However, traditionally analyzed biomarkers in urinalysis still lack sensitivity and specificity to accurately diagnose some diseases. Several studies have proposed the use of electronic noses (eNoses) for the analysis of volatile organic compounds in urine samples that may, directly or indirectly, correlate with certain pathologies. Hence, the aim of this study was to perform a systematic review and meta-analysis of studies concerning the use of portable electronic noses for diagnosis or monitoring of pathologies through analysis of urine samples. A systematic review of the literature was held according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Twenty-four articles met the inclusion criteria and were included in the analysis. The results of the revised studies showed that there are various volatile organic compound profiles, identified through eNose analysis, that may be applied for diagnosis or monitoring of several diseases, such as diabetes, urinary tract infection, inflammatory bowel disease, and kidney disease. A meta-analysis was conducted taking into consideration the data of 10 of the initial 24 articles. The pooled sensitivity, specificity, and diagnostic odds ratio were 84% (95% CI, 0.72-0.92), 85% (95% CI, 0.75-0.91), and 24.17 (95% CI: 7.85-74.41), respectively. The area under the receiver operating characteristic curve was 0.897. These results suggest that eNose technology has adequate diagnostic accuracy for several pathologies and could be a promising screening tool for clinical settings. However, more studies are needed to reduce heterogeneity between results.

Indexed as

diagnosiselectronic noseurinevolatile organic compounds

Identifiers

PMID37152083
PMCPMC10158878
OpenAlexW4311733597

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.