ArticleFrontiers in oncology2023
A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance.
Article in Frontiers in oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Beam geometry optimization and convergence mode evaluation for knowledge-based planning of hippocampal avoidance whole-brain radiotherapy: A cross-platform study with quantitative scorecard assessment.Journal of applied clinical medical physics · 2026Article
- Coplanar versus non-coplanar volumetric modulated arc therapy for hippocampal avoidance whole brain radiotherapy using Monte Carlo-based planning system.Radiological physics and technology · 2026Article
- Retrospective comparisons of the dosimetric differences between coplanar and non-coplanar volume-modulated arc therapy in patients with pediatric brainstem glioma.Oncology letters · 2025Article
- Article
- Positioning uncertainties in single-target longitudinal segmentation for hippocampal-avoidance whole brain radiotherapy using volumetric modulated arc therapy.Physics and imaging in radiation oncology · 2025Article
- Single Pontine Relapse Shortly After Hippocampal Avoidance Whole Brain Radiotherapy: A Case Report.Cancer reports (Hoboken, N.J.) · 2025Article
- Intensity-modulated proton therapy for hippocampal-sparing prophylactic cranial irradiation: a planning comparison with photon therapy.BMC cancer · 2025Article
- An innovative hippocampal-sparing whole-brain radiotherapy planning approach via the Halcyon system: achieving lower hippocampal doses.Frontiers in oncology · 2025Article
- Assessment of different head tilt angles in volumetric modulated arc therapy for hippocampus-avoidance whole-brain radiotherapy.Frontiers in oncology · 2024Article
- Hippocampal sparing in whole-brain radiotherapy for brain metastases: controversy, technology and the future.Frontiers in oncology · 2024Review
- Feasibility of flattening filter free beams for hippocampal avoidance whole-brain radiotherapy: a dosimetric and radiobiological analysis.Frontiers in oncology · 2023Article
- Comparison of Different Head Tilt Angles in Tomotherapy and Volumetric Modulated Arc Therapy for Hippocampal-Avoidance Whole-Brain Radiotherapy.Technology in cancer research & treatmentArticle
- Neurocognitive outcome of HS-WBRT vs WBRT in patients with brain metastases: A systematic review and meta-analysis.Neuro-oncology advancesArticle
- Delineation Errors Caused by Replication and Expansion Operations in Monaco.Technology in cancer research & treatmentArticle
- A Comprehensive Dosimetric and Plan Quality Evaluation of Non-coplanar VMAT With Flattening Filter-free Versus Flattened Beams for Hippocampal-Avoidance Whole-Brain Radiotherapy: A Multi-Platform Study on Elekta Infinity and UIH uRT-Linac Systems.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT). Methods: Ten patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively. Results: The dosimetric results of the three techniques complied roughly with the RTOG 0933 criteria. After dose normalization, the V Conclusion: The dosimetry of the three techniques for HA-WBRT could roughly comply with the proposals from RTOG 0933. After dose normalization (D
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.