Evidence map›Paper›PMID 37151806›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2023

Tunable neural networks for CT image formation.

Matthew Tivnan, Grace J Gang, Wenying Wang, Peter Noël, Jeremias Sulam, J Webster Stayman

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Application of an interpretable neural network framework based on the LASSO-proj algorithm for warfarin dose prediction].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matthew TivnanJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
Grace J GangJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-3882-0210
Wenying WangJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
Peter NoëlHospital of the University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0002-9671-6171
Jeremias SulamJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
J Webster StaymanJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0003-4358-378X

Funding

Nonlinear performance analysis and prediction for robust low dose lung CTR01CA249538 · NCI · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE · 2021 to 2024
$2.0M
NCI NIH HHS R01 CA249538
6 · The paper itself

Abstract

Optimization of CT image quality typically involves balancing variance and bias. In traditional filtered back-projection, this trade-off is controlled by the filter cutoff frequency. In model-based iterative reconstruction, the regularization strength parameter often serves the same function. Deep neural networks (DNNs) typically do not provide this tunable control over output image properties. Models are often trained to minimize the expected mean squared error, which penalizes both variance and bias in image outputs but does not offer any control over the trade-off between the two. We propose a method for controlling the output image properties of neural networks with a new loss function called weighted covariance and bias (WCB). Our proposed method uses multiple noise realizations of the input images during training to allow for separate weighting matrices for the variance and bias penalty terms. Moreover, we show that tuning these weights enables targeted penalization of specific image features with spatial frequency domain penalties. To evaluate our method, we present a simulation study using digital anthropomorphic phantoms, physical simulation of CT measurements, and image formation with various algorithms. We show that the WCB loss function offers a greater degree of control over trade-offs between variance and bias, whereas mean-squared error provides only one specific image quality configuration. We also show that WCB can be used to control specific image properties including variance, bias, spatial resolution, and the noise correlation of neural network outputs. Finally, we present a method to optimize the proposed weights for a spiculated lung nodule shape discrimination task. Our results demonstrate this new image quality can control the image properties of DNN outputs and optimize image quality for task-specific performance.

Indexed as

deep learning reconstructionneural networknoise correlationsspatial resolutiontask-based image qualityvariance bias trade-off

Identifiers

PMID37151806
PMCPMC10157542

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.