Evidence map›Paper›PMID 37150728›Full record

ArticleZeitschrift fur medizinische Physik2024

Post-mastectomy radiotherapy: Impact of bolus thickness and irradiation technique on skin dose.

Frédéric A Miéville, Nicolas Pitteloud, Vérane Achard, Giorgio Lamanna, Olivier Pisaturo, Pierre-Alain Tercier, Abdelkarim S Allal

Open access · goldAbstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Frédéric A MiévilleDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland. Electronic address: frederic.mieville@h-fr.ch.
Nicolas PitteloudDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Vérane AchardDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Giorgio LamannaDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Olivier PisaturoDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Pierre-Alain TercierDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Abdelkarim S AllalDepartment of Radiation Oncology, Hôpital Fribourgeois, 2-6 Chemin des Pensionnats, 1752 Villars-sur-Glâne, Fribourg, Switzerland.
Réseau Fribourgeois de Santé Mentale · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo determine 10 MV IMRT and VMAT based protocols with a daily bolus targeting a skin dose of 45 Gy in order to replace the 6 MV tangential fields with a 5 mm thick bolus on alternate days method for post-mastectomy radiotherapy.

methodWe measured the mean surface dose along the chest wall PTV as a function of different bolus thicknesses for sliding window IMRT and VMAT plans. We analyzed surface dose profiles and dose homogeneities and compared them to our standard 6 MV strategy. All measurements were performed on a thorax phantom with Gafchromic films while dosimetric plans were computed using the Acuros XB algorithm (Varian).

resultsWe obtained the best compromise between measured surface dose (mean dose and homogeneity) and skin toxicity threshold obtained from the literature using a daily 3 mm thick bolus. Mean surface doses were 91.4 ± 2.8% [85.7% - 95.4%] and 92.2 ± 2.3% [85.6% - 95.2%] of the prescribed dose with IMRT and VMAT techniques, respectively. Our standard 6 MV alternate days 5 mm thick bolus leads to 89.0 ± 3.7% [83.6% - 95.5%]. Mean dose differences between measured and TPS results were < 3.2% for depths as low as 2 mm depth.

conclusion10 MV IMRT-based protocols with a daily 3 mm thick bolus produce a surface dose comparable to the standard 6 MV 5 mm thick bolus on alternate days method but with an improved surface dose homogeneity. This allows for a better control of skin toxicity and target volume coverage.

Indexed as

Breast NeoplasmsMastectomyRadiotherapy DosageSkinFemaleHumansPhantoms, ImagingRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedBolusEBT3 filmIMRT/VMATPost-mastectomy radiation therapySurface skin doseThorax phantom

Identifiers

PMID37150728
PMCPMC11624419
OpenAlexW4375855642

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.