ArticleJournal of diabetes science and technology2023
Accuracy of Continuous Glucose Monitoring in an Insulin-Treated Population Requiring Haemodialysis.
Article in Journal of diabetes science and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Glycemic Patterns Revealed by Continuous Glucose Monitoring in Patients with Type 2 Diabetes Undergoing Intermittent Hemodialysis: A Pilot Study.Medical sciences (Basel, Switzerland) · 2026Observational
- Continuous glucose monitoring reveals distinct clinical implications of glucose levels at the start and end of hemodialysis in people with type 2 diabetes.BMC endocrine disorders · 2026Article
- Glucotypes in patients with type 2 diabetes and either diabetic kidney disease or end stage kidney disease under different anti-diabetic treatments.BMC endocrine disorders · 2025Article
- Hypoglycaemia episodes in older diabetic adults undergoing haemodialysis.Clinical kidney journal · 2025Article
- Scoping Review-Diabetes Technology for Individuals on Kidney Replacement Therapy (Dialysis): Current Trends and Future Directions.Journal of diabetes science and technology · 2025Review
- Review
- Performance of an interstitial glucose monitoring device in patients with type 1 diabetes during haemodialysis.Clinical kidney journal · 2024Article
- Continuous glucose monitoring in people with diabetes and end-stage kidney disease-review of association studies and Evidence-Based discussion.Journal of nephrology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundContinuous glucose monitoring (CGM) is revolutionizing diabetes care by giving both patients and the healthcare professionals unprecedented insights into glucose variability and patterns. It is established in National Institute for Health and Care Excellence (NICE) guidance as a standard of care for type 1 diabetes and diabetes in pregnancy under certain conditions. Diabetes mellitus (DM) is recognized as an important risk factor for chronic kidney disease (CKD). Around a third of patients receiving in-center haemodialysis as renal replacement therapy (RRT) have diabetes, either as a direct cause of renal failure or as an additional co-morbidity. Evidence of poor compliance with the current standard of care (self-monitoring of blood glucose [SMBG]) and overall greater morbidity and mortality, suggests this patient population as an ideal target group for CGM. However, there exists no strong published evidence showing the validity of CGM devices in insulin-treated diabetes patients requiring haemodialysis.
methodsWe applied a Freestyle Libre Pro sensor to 69 insulin-treated diabetes haemodialysis (HD) patients on a dialysis day. Interstitial glucose levels were obtained, and time matched within 7 minutes to capillary blood glucose testing and any plasma blood glucose levels sent. Data cleansing techniques were applied to account for rapidly correcting hypoglycaemia and poor SMBG technique.
resultsClarke-error grid analysis showed 97.9% of glucose values in an acceptable range of agreement (97.3% on dialysis days and 99.1% on non-dialysis days).
conclusionsWe conclude that the Freestyle Libre sensor is accurate in measuring glucose levels when compared to glucose as measured by capillary SMBG testing and laboratory obtained serum glucose in patients on HD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.