ArticleBMC musculoskeletal disorders2023
Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.
- Parallel versus non-parallel cannulated screw fixation for femoral neck fractures: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2026Pooled it
- What is the appropriate axial position in cannulated screw fixation for femoral neck fractures? A finite element analysis.BMC musculoskeletal disorders · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted triangular patterns. I am very sorry that a corresponding author needs to be added to the article. I do not know how to insert it, so I make a note here. Please check the attachment I uploaded.
methodsThe reasonableness of the model is first analyzed using finite elements. A total of 6 adult human specimens were selected, of which 3 males and 3 females were divided into the A1, B1, and C1 groups and the A2, B2, and C2 groups by the random number table method. The A1 and A2 groups were made into subhead femoral neck fracture models, the B1 and B2 groups were made into trans-neck femoral neck fracture models, and the C1 and C2 groups were made into basal femoral neck fracture models. The right femur of each group had a compression screw nail inserted in the crossed-inverted triangular pattern, and the left femur of each group had a compression screw nail inserted in the inverted triangular pattern. The static compression test was performed by an electronic universal testing machine. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were read according to the pressure-displacement curve drawn in the experiment.
resultsThe finite element analysis showed that the cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were greater than those of the right femur in the A1, A2, B1, B2 and C2 groups, while the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were smaller than those of the right femur in the C1 group. There was no statistically significant difference in the maximum load of the femoral neck or the load of 3.00 mm axial displacement of the femoral head between the A1 and A2 groups, the B1 and B2 groups, or the C1 and C2 groups (P > 0.05). After the K-S test, the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were normally distributed (P = 0.20), and the LSD-t test was conducted for the two load data; the difference was not statistically significant (P = 0.235).
conclusionThe effect of compression screw nails in the cross-inverted triangular pattern was the same in males and females, and stability was better in the fixation of subhead and trans-neck femoral neck fractures. However, its stability in fixation of basal femoral neck fracture is worse than that of the inverted triangular pattern. The cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail.
Indexed as