Effect of crown stiffness and prosthetic screw absence on the stress distribution in implant-supported restoration: A 3D finite element analysis.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 18 citations in OpenAlex.
- Tensile Retention of Lithium Disilicate and Zirconia Crowns Cemented to One-Piece Zirconia Implants: A Pilot In Vitro Study of Cementation Protocol, Resin Cement, and Micro-CT Cement Morphology.Materials (Basel, Switzerland) · 2026Article
- Finite Element Analysis of Stress Distribution in Healthy and Restored Mandibular Molars with Zirconia and Lithium Disilicate Crowns Under Vertical and Oblique Loading.Journal of functional biomaterials · 2026Article
- Stress distribution in three-unit implant-supported prostheses with different abutment designs: a finite element analysis.BMC medical informatics and decision making · 2026Article
- Comparison of lithium disilicate and feldspathic CAD-on systems in implant-supported crowns: a combined mechanical testing and FEA study.International journal of implant dentistry · 2026Article
- Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical Performance.Materials (Basel, Switzerland) · 2026Review
- The effect of varying the position of implant screw access opening on the stress distribution of sealing composite resin: a 3D-FEA study.BMC oral health · 2026Article
- Biomechanical evaluation of prosthetic framework materials in subperiosteal implants: a finite element analysis.BMC oral health · 2025Article
- Two-Phase Material Shape Optimization of an Additively Manufactured Integrated Metal and Ceramic Resin Implant-Supported Dental Crown.International journal for numerical methods in biomedical engineering · 2025Article
- Mechanical behavior of hybrid custom implant abutments with various crown materials: a 3D finite element analysis.BMC oral health · 2025Article
- Screening dental implant design parameters for effect on the fatigue limit of reduced-diameter implants.Dental materials : official publication of the Academy of Dental Materials · 2025Article
- Finite Element Analysis of Anterior Implant-Supported Restorations with Different CAD-CAM Restorative Materials.European journal of dentistry · 2025Article
- Dental Implant Abutment Screw Loss: Presentation of 10 Cases.Journal of functional biomaterials · 2024Article
- Effect of Antirotational Two-Piece Titanium Base on the Vertical Misfit, Fatigue Behavior, Stress Concentration, and Fracture Load of Implant-Supported Zirconia Crowns.Materials (Basel, Switzerland) · 2023Article
- Comparative Evaluation of the Effect of Implant Crown Materials on Implant Components and Bone Stress Distribution: A 3D Finite Element Analysis.International journal of dentistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This in-silico investigation evaluated the mechanical impact of Morse tape implant-abutment interface and retention system (with and without screw) and restorative materials (composite block and monolithic zirconia) by means of a three-dimensional finite element analysis (3D-FEA). Four 3D models were designed for the lower first molar. A dental implant (4.5 × 10 mm B&B Dental Implant Company) was digitized (micro CT) and exported to computer-aided design (CAD) software. Non-uniform rational B-spline surfaces were reconstructed, generating a 3D volumetric model. Four different models were generated with the same Morse-type connection, but with a different locking system (with and without active screw) and a different crown material made of composite block and zirconia. The D2 bone type, which contains cortical and trabecular tissues, was designed using data from the database. The implants were juxtaposed inside the model after Boolean subtraction. Implant placement depth was simulated for the implant model precisely at crestal bone level. Each acquired model was then imported into the finite element analysis (FEA) software as STEP files. The Von Mises equivalent strains were calculated for the peri-implant bone and the Von Mises stress for the prosthetic structures. The highest strain values in bone tissue occurred in the peri-implant bone interface and were comparable in the four implant models (8.2918e-004-8.6622e-004 mm/mm). The stress peak in the zirconia crown (64.4 MPa) was higher than in the composite crown (52.2 MPa) regardless of the presence of the prosthetic screw. The abutment showed the lowest stress peaks (99.71-92.28 MPa) when the screw was present (126.63-114.25 MPa). Based on this linear analysis, it is suggested that the absence of prosthetic screw increases the stress inside the abutment and implant, without effect on the crown and around the bone tissue. Stiffer crowns concentrate more stress on its structure, reducing the amount of stress on the abutment.