Evidence map›Paper›PMID 37143861›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

Multi-Body 3D-2D Registration for Robot-Assisted Joint Reduction: Preclinical Evaluation in the Ankle Syndesmosis.

R C Vijayan, K Venkataraman, J Wei, N M Sheth, B Shafiq, J H Siewerdsen, W Zbijewski, G Li, K Cleary, A Uneri

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Robot-Assisted Reduction of the Ankle Joint via Multi-Body 3D-2D Image Registration.IEEE transactions on medical robotics and bionics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

R C VijayanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
K VenkataramanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
J WeiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
N M ShethDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
B ShafiqDepartment of Orthopedic Surgery, Johns Hopkins Medicine, Baltimore MD.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
W ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
G LiChildren's National Hospital, Washington DC.
K ClearyChildren's National Hospital, Washington DC.
A UneriDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
Johns Hopkins University · USChildren's National · USThe University of Texas MD Anderson Cancer Center · US

Funding

Image-guided, robot-assisted reduction of joint dislocation in orthopaedic surgeryR01EB031958 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI UNERI, ALI · 2021 to 2024
$2.6M
NIBIB NIH HHS R01 EB031958
6 · The paper itself

Abstract

Purpose: Existing methods to improve the accuracy of tibiofibular joint reduction present workflow challenges, high radiation exposure, and a lack of accuracy and precision, leading to poor surgical outcomes. To address these limitations, we propose a method to perform robot-assisted joint reduction using intraoperative imaging to align the dislocated fibula to a target pose relative to the tibia. Methods: The approach (1) localizes the robot via 3D-2D registration of a custom plate adapter attached to its end effector, (2) localizes the tibia and fibula using multi-body 3D-2D registration, and (3) drives the robot to reduce the dislocated fibula according to the target plan. The custom robot adapter was designed to interface directly with the fibular plate while presenting radiographic features to aid registration. Registration accuracy was evaluated on a cadaveric ankle specimen, and the feasibility of robotic guidance was assessed by manipulating a dislocated fibula in a cadaver ankle. Results: Using standard AP and mortise radiographic views registration errors were measured to be less than 1 mm and 1° for the robot adapter and the ankle bones. Experiments in a cadaveric specimen revealed up to 4 mm deviations from the intended path, which was reduced to <2 mm using corrective actions guided by intraoperative imaging and 3D-2D registration. Conclusions: Preclinical studies suggest that significant robot flex and tibial motion occur during fibula manipulation, motivating the use of the proposed method to dynamically correct the robot trajectory. Accurate robot registration was achieved via the use of fiducials embedded within the custom design. Future work will evaluate the approach on a custom radiolucent robot design currently under construction and verify the solution on additional cadaveric specimens.

Identifiers

PMID37143861
PMCPMC10155864
OpenAlexW4362487732

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.