Evidence map›Paper›PMID 37142565›Full record

ArticleLight, science & applications2023

Apochromatic X-ray focusing.

Umut T Sanli, Griffin Rodgers, Marie-Christine Zdora, Peng Qi, Jan Garrevoet, Ken Vidar Falch, Bert Müller, Christian David, Joan Vila-Comamala

Abstract read
In one paragraph

Article in Light, science & applications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. An achromatic neutron lens.Nature communications · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Umut T Sanli *Paul Scherrer Institute, Laboratory for X-ray Nanoscience and Technologies, Forschungsstrasse 111, 5232, Villigen, Switzerland. umut.sanli@psi.ch.
Griffin Rodgers *Biomaterials Science Center, Department of Biomedical Engineering, University of Basel, Hegenheimermattweg 167 B, 4123, Allschwil, Switzerland.
Marie-Christine ZdoraPaul Scherrer Institute, Laboratory for X-ray Nanoscience and Technologies, Forschungsstrasse 111, 5232, Villigen, Switzerland.ORCID http://orcid.org/0000-0001-6953-6709
Peng QiPaul Scherrer Institute, Laboratory for X-ray Nanoscience and Technologies, Forschungsstrasse 111, 5232, Villigen, Switzerland.ORCID http://orcid.org/0000-0001-6612-9550
Jan GarrevoetDeutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.ORCID http://orcid.org/0000-0001-8696-0499
Ken Vidar FalchDeutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Bert MüllerBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Hegenheimermattweg 167 B, 4123, Allschwil, Switzerland.
Christian DavidPaul Scherrer Institute, Laboratory for X-ray Nanoscience and Technologies, Forschungsstrasse 111, 5232, Villigen, Switzerland.
Joan Vila-ComamalaPaul Scherrer Institute, Laboratory for X-ray Nanoscience and Technologies, Forschungsstrasse 111, 5232, Villigen, Switzerland.ORCID http://orcid.org/0000-0002-1543-3146

Funding

EC | Horizon 2020 Framework Programme (EU Framework Programme for Research and Innovation H2020) 884104
6 · The paper itself

Abstract

Achromatic doublets are combinations of two individual lenses designed to focus different wavelengths of light in the same position. Apochromatic optics are improved versions of the achromatic schemes which extend the wavelength range significantly. Both achromatic and apochromatic optics are well-established for visible light. However, X-ray achromatic lenses did not exist until very recently, and X-ray apochromatic lenses have never been experimentally demonstrated. Here, we create an X-ray apochromatic lens system using an appropriate combination of a Fresnel zone plate and a diverging compound refractive lens with a tuned separation distance. The energy-dependent performance of this apochromat was characterized at photon energies between 6.5 and 13.0 keV by ptychographic reconstruction of the focal spot and scanning transmission X-ray microscopy of a resolution test sample. The apochromat delivered a reconstructed focal spot size of 940 × 740 nm

Identifiers

PMID37142565
PMCPMC10160054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.