Comparative evaluation of three commercially available markerless depth sensors for close-range use in surgical simulation.

Lukas Burger, Lalith Sharan, Roger Karl, Christina Wang, Matthias Karck, Raffaele De Simone, Ivo Wolf, Gabriele Romano, Sandy Engelhardt

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lukas Burger *Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0003-4480-6076
Lalith Sharan *Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany. lalithnag.sharangururaj@med.uni-heidelberg.de.ORCID http://orcid.org/0000-0003-0835-042X
Roger KarlDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0003-4732-8495
Christina WangDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Matthias KarckDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Raffaele De SimoneDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Ivo WolfDepartment of Computer Science, Mannheim University of Applied Sciences, Mannheim, Germany.
Gabriele RomanoDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0002-6843-4492
Sandy EngelhardtDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0001-8816-7654

Funding

Deutsche Forschungsgemeinschaft 398787259, DE 2131/2-1 and EN 1197/2-1Klaus Tschira Stiftung 398787259, DE 2131/2-1 and EN 1197/2-1
6 · The paper itself

Abstract

purposeMinimally invasive surgeries have restricted surgical ports, demanding a high skill level from the surgeon. Surgical simulation potentially reduces this steep learning curve and additionally provides quantitative feedback. Markerless depth sensors show great promise for quantification, but most such sensors are not designed for accurate reconstruction of complex anatomical forms in close-range.

methodsThis work compares three commercially available depth sensors, namely the Intel D405, D415, and the Stereolabs Zed-Mini in the range of 12-20 cm, for use in surgical simulation. Three environments are designed that closely mimic surgical simulation, comprising planar surfaces, rigid objects, and mitral valve models of silicone and realistic porcine tissue. The cameras are evaluated on Z-accuracy, temporal noise, fill rate, checker distance, point cloud comparisons, and visual inspection of surgical scenes, across several camera settings.

resultsThe Intel cameras show sub-mm accuracy in most static environments. The D415 fails in reconstructing valve models, while the Zed-Mini provides lesser temporal noise and higher fill rate. The D405 could reconstruct anatomical structures like the mitral valve leaflet and a ring prosthesis, but performs poorly for reflective surfaces like surgical tools and thin structures like sutures.

conclusionIf a high temporal resolution is needed and lower spatial resolution is acceptable, the Zed-Mini is the best choice, whereas the Intel D405 is the most suited for close-range applications. The D405 shows potential for applications like deformable registration of surfaces, but is not yet suitable for applications like real-time tool tracking or surgical skill assessment.

Indexed as

Mitral Valve InsufficiencySurgeonsAnimalsComputer SimulationHumansMinimally Invasive Surgical ProceduresMitral ValveSwineDepth sensorsEvaluationSurgerySurgical simulator

Identifiers

PMID37140737
PMCPMC10284995

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.